ESC13-00943
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 4:00:54 PM | | PASS |
|
|
New parking lot and drainage swale has been installed. Construction equipment still on-site with some grading and vegetation working remaining. All work contained within HP campus, access through Cloverdale gate. Perimeter wattles installed along portion of Chinden. No sediment leaving site. Approved.
|
ESC11-00879
| Random Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 3:29:58 PM | P | PART |
|
|
Some wattles have been restored but contractors still accessing bare lots and driving over wattles. Need to conduct maintenance on downslope BMPs and post signage to stop contractors from causing trackout.
Cement washout for new sites has been moved up above next Somerset Village #3. A construction entrance will need to be provided once the washout is in use.
|
ESC13-00835
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 2:46:49 PM | | PASS |
|
|
No violations at this time. Requested no offstreet parking allowed.
|
ESC13-00204
| Aging Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 1:44:19 PM | | PASS |
|
|
Finaled.
|
ESC13-00204
| DOC - Permit Finaled | 1/15/2014 | 1/15/2014 | 1/15/2014 1:42:26 PM | P | PASS |
|
|
Addition is complete. Yard is stabilized. All permits finaled except BLD. No activity on BLD for >6 months. ESC conditions met, no further inspections required.
|
ESC13-00781
| BMP Violation | 1/15/2014 | 1/15/2014 | 1/15/2014 1:28:58 PM | P | PART |
|
|
rescheduled inspection from AM.
Corrections complete: 1. Trash has been picked up and discarded. 2. Sidewalks, driveway have been swept, some minor trackout 3. Wattles along east side of lot behind railroad ties have been retrenched/installed up to driveway. 4. RP did call for re-inspection as directed. Corrections remaining: 1. 15-20ft of wattles to west of driveway need to be installed. Unvegetated hillslope.
2. Washout still needs to be removed, but surrounding area has been cleaned. Need a bobcat or jackhammer to dispose washout. RP stated all concrete work is complete.
3. Some gutter sweeping still needs tending to when vehicles & trailers are removed.
Called RP and extended time to become in full compliance. Will re-inspect per directives from ESC coordinator.
|
ESC13-01064
| Random Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 1:01:38 PM | P | FAIL |
|
|
Need to clean up sidewalks, portion of intersection on Sawmill and Mill Station, and access alleyway.
Verbal CN issued:
RP Braxton of Brighton Homes agreed to have street sweeper come after 5 pm today. Will re-inspect tomorrow.
|
ESC13-00684
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 12:54:01 PM | | PASS |
|
|
Conducted full perimeter walk around. Area of disturbance clearly delineated by berms and concrete blocking that will serve as foundation for fence. Vegetatative barrier was kept in tact outside of concrete blocking.
Met contractor/owner Pat on-site and discussed BMPs. Construction entrance was refilled 1/14; weekly inspections for SWPPP performed by Syman Co.
No corrections at this time.
|
ESC13-00259
| Aging Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 12:22:37 PM | | PASS |
|
|
No hillside erosion or channel washouts observed - stabilization and hillside drainage divirsion appear effective. Perimter BMPs prevented muddy runoff onto streets at east end. Some stockpiles in middle of site currently. No corrections at this time.
|
ESC13-00793
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 12:22:20 PM | | PASS |
|
|
Construction entrance and silt fence perimeter in good condtion around laydown yard.
Will need to replenish entrance to Terraces main site next week, but is ok for now.
Note - lots of sand on round-a-bout due to ACHD winter road sanding.
|
ESC13-00781
| BMP Violation | 1/14/2014 | 1/15/2014 | 1/15/2014 11:59:57 AM | A | PART |
|
|
To see if RP addressed all BMP violations
RP finished all corrections but washout per phone call. Onsite inspection rescheduled for PM
|
ESC13-00920
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 11:31:38 AM | | PASS |
|
|
Working on laying new sidewalk - no sidewalk previously.. House complete yard not landscaped yet. Street is being kept clean during work. No corrections at this time. Will need to remove stormwater DI protection when complete/stabilized.
|
ESC13-00892
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 10:36:51 AM | | FAIL |
|
|
Two corrections:
1. Replenish construction entrance 2. Sweep street in front of site.
Talked to RP Mark on phone, they will make changes starting today. Reinspection scheduled for Friday AM.
|
ESC13-00940
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 10:34:11 AM | | PASS |
|
|
Grass has been planted. No activity. Next inspection may be ready to final.
|
ESC13-00601
| Aging Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 9:59:11 AM | | PASS |
|
|
Structure is erected, but some work and stabilization remains. Gravel stockpiles on-site. No corrections at this time.
|
ESC13-00561
| Conference | 1/14/2014 | 1/15/2014 | 1/15/2014 9:39:40 AM | A | PASS |
|
|
Jared Phone #: ###-####
Conference was called to discuss engineering changes to building's new stormwater drainage. Needs to be reviewed by PW Engineer. Provided contact info for Brian Murphy.
No ESC violations observed while on-site.
|
ESC13-00843
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 9:04:15 AM | | PASS |
|
|
No earthwork or construction materials stored outdoors. Work mainly on interior. No violations observed at Edge Brewery renovation.
|
ESC13-00044
| General Inspection | 1/15/2014 | 1/15/2014 | 1/15/2014 8:28:50 AM | | PASS |
|
|
|
ESC13-00781
| General Inspection | 1/14/2014 | 1/15/2014 | 1/15/2014 7:46:17 AM | A | CANC |
|
|
Joe Phone #: ###-####
Duplicate inspection entry. See BMP violation inspection.
|