ELE15-03729
| Final | 1/15/2016 | 1/15/2016 | 1/15/2016 2:06:35 PM | P | PART |
|
|
Partial Final for 1st Floor Units Phone #: ###-#### Inspection requested via web by Kerri Hamilton units 101,116,117 partial ok to occupy
|
ELE15-03729
| Electrical Rough-In | 1/15/2016 | 1/15/2016 | 1/15/2016 2:04:52 PM | P | PASS |
|
|
Rough in for 2nd Floor Units Phone #: ###-#### Inspection requested via web by Kerri Hamilton units 203,204,214,215 ok cover
|
ELE16-00061
| Rough-In Permanent Service | 1/15/2016 | 1/15/2016 | 1/15/2016 1:18:39 PM | P | PASS |
|
|
Access thru alley if possible Phone #: ###-#### Inspection requested via web by Lars Johnson detached garage and living quarters ok cover p/s oh rec ok
|
ELE15-03640
| Electrical Rough-In | 1/15/2016 | 1/15/2016 | 1/15/2016 12:53:27 PM | P | CANC |
|
|
will Phone #: ###-#### no access, called and left message
|
ELE16-00129
| Electrical Rough-In | 1/15/2016 | 1/15/2016 | 1/15/2016 11:01:22 AM | P | PASS |
|
|
concrete encased electrode ok cover
|
ELE16-00120
| Temporary Service | 1/15/2016 | 1/15/2016 | 1/15/2016 11:00:35 AM | P | PASS |
|
|
Mike Phone #: ###-#### t/s u/g n ok
|
ELE16-00119
| Temporary Service | 1/15/2016 | 1/15/2016 | 1/15/2016 10:59:56 AM | P | PASS |
|
|
Mike Phone #: ###-#### t/s u/g n ok
|
ELE16-00129
| Final | 1/14/2016 | 1/15/2016 | 1/15/2016 10:42:13 AM | A | CANC |
|
|
Ufer inspection Phone #: ###-#### Inspection requested via web by kendall bender needed rough-in only
|
ELE16-00129
| Temporary Service | 1/15/2016 | 1/15/2016 | 1/15/2016 10:41:43 AM | P | CANC |
|
|
Ufer inspection Phone #: ###-#### Inspection requested via web by kendall bender t/s u/g n ok
|
ELE16-00078
| Temporary Service | 1/14/2016 | 1/15/2016 | 1/15/2016 10:16:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE15-03408
| Final | 1/11/2016 | 1/15/2016 | 1/15/2016 10:10:12 AM | A | FAIL |
|
|
please call homeowner at ###-#### to arrange for entry. Thanks if any ? call Bill ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn 406.4 (5) tamper resistant receptacles required BCO 4-05-23 unlawful to conceal or cover items to be inspected cannot gain access to receptacles due to homeowners moved in proir to inspection
|
ELE16-00123
| Temporary Service | 1/14/2016 | 1/15/2016 | 1/15/2016 9:18:02 AM | A | PASS |
|
|
Jake// please call before Phone #: ###-#### t/s u/g n ok
|
ELE16-00121
| Final | 1/14/2016 | 1/15/2016 | 1/15/2016 9:03:56 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Celinda Winters 440.22(c) protective device shall not exceed manufacturers rating 210.63 service receptacle shall be located within 25'
|