ELE96-02629
| INSP - Electrical Rough-In | 1/15/1997 | 1/16/1997 | 1/16/1997 12:00:00 AM | A | FAIL |
|
|
01/15/97 403 - NEC: 210-52(D). IN DWELLING UNITS, AT LEAST ONE WALL RECEPTICLE OUTLET SHALL BE INSTALLED IN BATHROOMS ADJACENT TO EACH BASIN LOCATION. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. NEC: 210-8(A)(1). BATHROOMS SHALL HAVE G.F.C.I. PROTECTION FOR PERSONNEL. B.C.C. 1205-C. IN-HOUSE FANS SHALL HAVE A MANUAL SWITCH AND AUTOMATIC TIMER SWITCH.
|
ELE97-00128
| INSP - Electrical Rough-In | 1/15/1997 | 1/16/1997 | 1/16/1997 12:00:00 AM | A | PASS |
|
|
01/16/97 403 - PARING IN CABINERS AND ADD PLUGS..3RD FLOOR..COMMISSIONER NO OCCUPANCY OR INSPECTION CARD FOR ELECTRICAL DEPARTMENT TO SIGN, LEFT NOTICE...MB
|
ELE97-00128
| INSP - Final | 1/15/1997 | 1/16/1997 | 1/16/1997 12:00:00 AM | P | PASS |
|
|
inspection card located, ele-r/i and final requested at same time. signed in molley's office...mb
|
ELE97-00137
| INSP - Conference | 1/16/1997 | 1/16/1997 | 1/16/1997 12:00:00 AM | P | PASS |
|
|
01/16/97 403 -
|
ELE96-03221
| INSP - Final | 1/16/1997 | 1/16/1997 | 1/16/1997 12:00:00 AM | P | NR |
|
|
01/16/97 403 - SIGN INFORMED ABOUT FRESHLY STAINED HARDWOOD FLOORS AND W 1-17-97 A.M...MB
|