ELE05-03636
| ELE-Aging Inspection | 1/16/2007 | 1/16/2007 | 1/18/2007 10:11:26 AM | | FAIL |
|
|
corrections not made
|
ELE05-00058
| ELE-Aging Inspection | 1/16/2007 | 1/16/2007 | 1/18/2007 9:57:33 AM | | DONE |
|
|
contr needs to call for inspection
|
ELE05-03803
| ELE-Aging Inspection | 1/16/2007 | 1/16/2007 | 1/18/2007 9:56:07 AM | | DONE |
|
|
suc
|
ELE07-00154
| Electrical Rough-In | 1/15/2007 | 1/16/2007 | 1/16/2007 4:21:32 PM | P | PASS |
|
|
Cover inspection for garden shed in back yard. Thank you! Phone #: ###-#### called contr, talked with owner, u/g appears to be ok, covered with water line for depth, only 2 90's, ric shed ok
|
ELE07-00076
| Electrical Rough-In | 1/16/2007 | 1/16/2007 | 1/16/2007 3:47:12 PM | P | PASS |
|
|
underground//Brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g ok to cover house to garage only
|
ELE06-03427
| Electrical Rough-In | 1/16/2007 | 1/16/2007 | 1/16/2007 3:04:49 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/16/2007 at 7:45:29 AM. Contact: ###-####. called left corr notice, nec 110.12(A) unused openings in boxes shall be closed, 330.30(A) mc cable bend radius shall be 7x diameter of cable,330.30(B) mc cable sahll be strapped within 12" of box, 300.4(A)&(D) edge of bored holes and mc cable shall be 1 1/4" from edge of framing members
|
ELE07-00155
| Electrical Rough-In | 1/16/2007 | 1/16/2007 | 1/16/2007 2:59:08 PM | P | NH |
|
|
Rough in inspection Phone #: ###-#### called, left message, left card, no access
|
ELE06-04570
| Permanent Service | 1/16/2007 | 1/16/2007 | 1/16/2007 1:59:19 PM | P | PASS |
|
|
Phone #: ###-#### p/s exst meter pak n ok
|
ELE05-04325
| Electrical Rough-In | 1/16/2007 | 1/16/2007 | 1/16/2007 1:17:18 PM | P | PART |
|
|
Jason; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt hard lid 1st fl corridor anop ok to cover, upper floors dropped ceilings nr
|
ELE06-00293
| Conference | 1/11/2007 | 1/16/2007 | 1/16/2007 11:06:52 AM | A | DONE |
|
|
Jeran ###-####//please call 30 min prior to meet you talked about gec, panel change and what to do for ri
|
ELE07-00148
| Electrical Rough-In | 1/12/2007 | 1/16/2007 | 1/16/2007 10:56:51 AM | A | PASS |
|
|
Tech/ Dan ###-#### for Range ckt & two outdoor recepts on pool side of house. Tech/ Jason ###-#### for other two outside recepts. Phone #: ###-#### ric ok, see final
|
ELE07-00148
| Final | 1/16/2007 | 1/16/2007 | 1/16/2007 10:56:00 AM | A | PASS |
|
|
Tech/ Dan ###-#### for Range ckt & two outdoor recepts on pool side of house. Tech/ Jason ###-#### for other two outside recepts. Phone #: ###-#### ok to final
|
ELE06-02468
| Electrical Rough-In | 1/15/2007 | 1/16/2007 | 1/16/2007 10:39:32 AM | A | PART |
|
|
CONTACT: JOHN STEBLY - CEILING INSPECTION Phone #: ###-#### n and s entry soffits only ok to cover
|
ELE06-04065
| Final | 1/15/2007 | 1/16/2007 | 1/16/2007 9:31:21 AM | A | PASS |
|
|
READY FOR FINAL RE-INSPECTION. THANKS Phone #: ###-#### corr made, ok to final
|
ELE06-04065
| Permanent Service | 1/16/2007 | 1/16/2007 | 1/16/2007 9:30:14 AM | A | CANC |
|
|
READY FOR FINAL RE-INSPECTION. THANKS Phone #: ###-#### p/s o/h rec ok
|
ELE06-03931
| Final | 1/15/2007 | 1/16/2007 | 1/16/2007 9:16:54 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/15/2007 at 3:30:30 PM. Contact: ###-####. ok to final, no card to sign
|
ELE07-00145
| Electrical Rough-In | 1/12/2007 | 1/16/2007 | 1/16/2007 8:46:25 AM | A | PASS |
|
|
rick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok
|
ELE06-03829
| Final | 1/12/2007 | 1/16/2007 | 1/16/2007 8:27:41 AM | A | NR |
|
|
Requesting a Final inspection. Please use the West entrance. Phone #: ###-#### not done, see ri for ceilings
|
ELE06-03829
| Electrical Rough-In | 1/12/2007 | 1/16/2007 | 1/16/2007 8:26:57 AM | A | PART |
|
|
Requesting inspection to cover ceilings. Please use the West entrance. Phone #: ###-#### 1st floor north of hall and east 1/2 only ok to cover clg, fire alarm and lv not terminated , called contr, need panel scheds, no wiring to be left on grid, find out what balance of work is and who doing, no upstairs inspections done yet, no inspections in existing parts of bldg done yet
|
ELE06-02468
| Electrical Rough-In | 1/15/2007 | 1/16/2007 | 1/15/2007 9:40:51 AM | P | CANC |
|
|
CONTACT: JOHN STEBLY - CEILING INSPECTION Phone #: ###-#### Inspection cancelled from web by: Deb McCoy
|