Inspections for the day of: Tuesday, January 16, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorWilliam E Thomas
TitleELE-INSPECTOR
Phone #794-9492
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00086 Rough-In Permanent Service1/16/20071/16/20071/16/2007 4:17:59 PMPPASS
Phone #: ###-####
1.ri ok
2. p/s u/g n ok
ELE07-00023 Electrical Rough-In1/16/20071/16/20071/16/2007 4:12:23 PMPPASS
Call Dan Surerus with any questions at ###-####
Phone #: ###-####
1. ri ok, new walls and fished walls
ELE07-00159 Temporary Service1/16/20071/16/20071/16/2007 3:26:16 PMPPASS
###-#### - bob
t/s o/h n ok
ELE07-00156 Permanent Service1/16/20071/16/20071/16/2007 2:12:10 PMPNR
Phone #: ###-####
not ready
ELE07-00051 Electrical Rough-In1/16/20071/16/20071/16/2007 2:07:35 PMPFAIL
chad; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
110.3 manu instr for nm box
334.30securing cables within 12"
210.70 lighting outlet in stairwell
B.C.C. no violations shall remain- ko seals, cable straps in boxes, water ground.
ELE07-00160 Temporary Service1/16/20071/16/20071/16/2007 2:03:56 PMPPASS
Need overhead temp pole inspected for hook up, back side of lot, alley access. Phone #: ###-####
t/s o/h n ok
ELE07-00149 Final1/12/20071/16/20071/16/2007 11:24:03 AMAPASS
jessie ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
ELE07-00023 Electrical Rough-In1/12/20071/16/20071/16/2007 11:20:19 AMACANC
Call Dan Surerus with any questions at ###-####
Phone #: ###-####
wrong address
ELE07-00003 Electrical Rough-In1/12/20071/16/20071/16/2007 11:18:59 AMAPASS
Phone #: ###-####
1. north east wall ok to cover
2. cieling ok from corridor to west side of building
ELE06-02663 Final1/15/20071/16/20071/16/2007 10:31:32 AMAPASS
###-#### garage code 1492
ELE06-00313 Electrical Rough-In1/12/20071/16/20071/16/2007 9:49:27 AMAPASS
trent, note: bathroom wall inspection; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
bathroom ri ok walls and cieling
ELE07-00153 Electrical Rough-In1/15/20071/16/20071/16/2007 9:28:04 AMAPASS
READY FOR ROUGH IN INSPECTION FOR RELOCATION OF MACHINE SHOP & ADJUST ELECTRIC IN WAREHOUSE. SEE KEVIN ON SIGHT @###-#### FOR AREAS TO BE INSPECTED. THANK YOU. Phone #: ###-#### x0000
1. ri ok new wall only.
ELE07-00064 Final1/12/20071/16/20071/16/2007 9:06:58 AMACANC
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
ELE07-00147 Electrical Rough-In1/12/20071/16/20071/16/2007 8:44:38 AMAPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
1. slab floor cover ok