ESC13-00781
| BMP Violation | 1/15/2014 | 1/16/2014 | 1/16/2014 4:33:07 PM | P | PASS |
|
|
2nd inspection of site to check for remaining corrections.
Site has been brought back into compliance. Permit posted. Wattle installed to east of driveway Sidewalks and driveway swept. Litter picked up
Next incident will result in re-inspection fees and/or stop-work-order.
|
ESC13-00213
| General Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 4:17:15 PM | | PASS |
|
|
Hillside stabilization has been effective with the hydromulch with tacifier. Street and driveway will need sweeping next week. No corrections at this time. No discharge or sediment coming to street. Just track out from vehicles and boots.
|
ESC13-00524
| Complaint Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 3:25:01 PM | P | PART |
|
|
PW Jim Wylie commented on some rill erosion. Need to check it out.
Inspection conducted by Evan and myself. Hillside rilling evident in some areas, some wattles failed during snowmelt. , considering size and scope many BMPs were effective.
Talked to Central Paving RP Bob Berryman and issued following corrections:
1. Need to conduct SWPPP inspections and update construction schedule/project status. 2. Repair damaged/untrenched wattles as necessary. 3. Address several slope areas between graded flat lots where rill erosion is evident. i.e. repair containment berms, place rip rap to guide, or other applicable BMP 4. Finish hydroseeding schedules where no further work/disturbance is scheduled.
note: developer Scott Kimball was also notified.
|
ESC13-00599
| Aging Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 12:28:05 PM | | PASS |
|
|
Finaled.
|
ESC13-00599
| DOC - Permit Finaled | 1/16/2014 | 1/16/2014 | 1/16/2014 12:27:53 PM | P | PASS |
|
|
House complete and landscaped. Up for sale. Culdesac with 3 homes has been cleaned and no materials or stockpiles remain. ESC conditions satisfied.
|
ESC13-00637
| Aging Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 12:27:35 PM | | PASS |
|
|
Finaled.
|
ESC13-00637
| DOC - Permit Finaled | 1/16/2014 | 1/16/2014 | 1/16/2014 12:27:09 PM | P | PASS |
|
|
House complete and landscaped. Up for sale. Culdesac with 3 homes has been cleaned and no materials or stockpiles remain. ESC conditions satisfied.
|
ESC13-00966
| General Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 12:14:48 PM | | PASS |
|
|
No activity, project hasn't started.. Lots are at end of Talavera by canal.
|
ESC13-00972
| Tracking Control | 1/16/2014 | 1/16/2014 | 1/16/2014 12:06:13 PM | A | FAIL |
|
|
Written Correction Notice posted.
1. Clean up sidewalk and alley. Check filter bags. 2. Provide construction entrance for cement washout. 3. Empty washout, new washout should be lined and labeled.
Called new Hunter Homes RP Austin ###-#### to inform him. Compliance date 1/20/14
|
ESC13-00633
| Aging Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 11:45:16 AM | | PASS |
|
|
Finaled.
|
ESC13-00633
| DOC - Permit Finaled | 1/16/2014 | 1/16/2014 | 1/16/2014 11:44:58 AM | P | PASS |
|
|
House complete, stabilized, and landscaped. All other permits finaled. No further ESC inspections required.
|
ESC11-00732
| General Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 11:40:44 AM | | PASS |
|
|
No acitivity. No change in status. Will keep open to monitor area for time being.
|
ESC13-00951
| General Inspection | 1/16/2014 | 1/16/2014 | 1/16/2014 11:26:49 AM | | CANC |
|
|
No activity. No violations. Permit posted.
|
ESC13-01143
| Site Preparation | 1/16/2014 | 1/16/2014 | 1/16/2014 11:21:58 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Braxton Hansen
No activity yet, Permit is posted on Mill Station. Townhome so tight spot, two lots side by side.. Approved to start, but conditional on order to clean up streets and sidewalks in Mill Square due Friday AM.
|
ESC13-01142
| Site Preparation | 1/16/2014 | 1/16/2014 | 1/16/2014 11:21:31 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Braxton Hansen
No activity yet, Permit is posted on Mill Station. Townhome so tight spot, two lots side by side.. Approved to start, but conditional on order to clean up streets and sidewalks in Mill Square due by Friday AM
|
ESC13-01064
| BMP Violation | 1/15/2014 | 1/16/2014 | 1/15/2014 4:31:45 PM | A | CANC |
|
|
Braxton called and said that sweeper company cancelled rounds for 1/15 and rescheduled for Thursday eve. Will inspect Friday.
|