ELE15-00096
| Final | 1/16/2015 | 1/16/2015 | 1/16/2015 3:49:25 PM | P | FAIL |
|
|
Per Jim Sly - Call Diana 30min prior at ###-####. Work done prior to moving in, need to know what needs to be done for final inspection 210.12- AFCI shall feed all outlets located in bed room. Open ground at GFCI at bottom of stairs
|
ELE15-00110
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 3:48:18 PM | P | PASS |
|
|
Added bath fan to bath Phone #: ###-#### Inspection requested via web by Randy Fletcher Final ok
|
ELE15-00114
| Electrical Rough-In | 1/15/2015 | 1/16/2015 | 1/16/2015 3:02:23 PM | P | PASS |
|
|
Trenching inspection. Cal Doug at ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Barbara Szurgot Under slab just in front door rough in ok cover
|
ELE14-02082
| Electrical Rough-In | 1/16/2015 | 1/16/2015 | 1/16/2015 2:44:54 PM | P | PASS |
|
|
ceiling - Mike (bldg super) Phone #: ###-#### Office area grid rough in ok cover
|
ELE14-03292
| Electrical Rough-In | 1/14/2015 | 1/16/2015 | 1/16/2015 2:18:07 PM | P | FAIL |
|
|
Timothy Phone #: ###-#### Shall finish wiring 3-way, 300.4- Shall protect NM cable where ran through bored holes less than 1 1/4" from framing surface.Abrasion protection where NM cable enters panel. Replace 3 wire dryer feed to 4- wire.
|
ELE15-00097
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 1:05:36 PM | A | PART |
|
|
Temporary final machine not on site yet need occupancy to bring machine in. Phone #: ###-#### Inspection requested via web by Thomas Jenkins No work performed in any other areas. Temp final ok
|
ELE15-00097
| Electrical Rough-In | 1/16/2015 | 1/16/2015 | 1/16/2015 1:04:08 PM | P | PASS |
|
|
Temporary final machine not on site yet need occupancy to bring machine in. Phone #: ###-#### Inspection requested via web by Thomas Jenkins Power feed to transformer and disconnecting means for laser machine and compressor. Rough in ok
|
ELE14-03551
| Electrical Rough-In | 1/15/2015 | 1/16/2015 | 1/16/2015 12:26:30 PM | A | PASS |
|
|
ceiling Phone #: ###-#### Inspection requested via web by Bryan McLaughlin Entrance between Dillards and Kohls, just inside to right. Grid rough in ok cover.
|
ELE15-00113
| Electrical Rough-In | 1/16/2015 | 1/16/2015 | 1/16/2015 12:18:30 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack Inspection cancelled from web by: Lee VanSchoiack
|
ELE14-03112
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 11:55:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve ragan Service change Final ok
|
ELE13-01058
| Electrical Rough-In | 1/16/2015 | 1/16/2015 | 1/16/2015 11:31:31 AM | P | CANC |
|
|
we are also doing exterior lights to new DLC list UL/ETL listed LED at this building. Phone #: ###-#### >> Inspection requested via web by Tim Dunlop Inspection cancelled from web by: Tim Dunlop
|
ELE14-02318
| Final | 1/16/2015 | 1/16/2015 | 1/16/2015 11:29:23 AM | A | PART |
|
|
Brian Phone #: ###-#### Freezer area ok. Waiting on 2 cord end adapters for portable equiptment. 400.8 Flexible cord that powers fan on the exterior of existing portion of freezer shall be refed by a permanant wiring method and shall not be supported by metal water piping system. Available fault current shall be posted of new service gear.
|
ELE15-00115
| Electrical Rough-In | 1/15/2015 | 1/16/2015 | 1/16/2015 10:39:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Floor heat installed in entry hall, powder bath, kitchen, family rm, and laundry all controlled at bottom of stairs. Rough in ok cover
|
ELE14-02557
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 9:56:23 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve ragan Retaining wall final ok
|
ELE14-02943
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 9:25:20 AM | A | FAIL |
|
|
Josh is contact. Thanks Phone #: ###-#### Inspection requested via web by Chris Chesnut 210.8- All garage receptacle outlets 120 volt 15 -20 amp shall have GFCI protection. 210.8- Recetacle outlet in unfinished basement shall have GFCI protection. 210.70(A)(3)- Unfinished basement shall have at least 1 lighting outlet controlled by wall switch installed. 314.16- Island outlet boxes shall have sufficient capacity for conductors and device. 8ci box min of 10 needed. 410.16- Master closet luminaires shall have totally enclosed lamps. * Master bath outlets dead. * Unable to verify GFCI protection for master bath floor heat. BCC- At least 50% of lamp shall be energy effient type.
|
ELE15-00083
| Final | 1/15/2015 | 1/16/2015 | 1/16/2015 8:08:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Felin Service reconnect Final ok
|