Inspections for the day of: Tuesday, January 16, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01337 Electrical Rough-In1/16/20181/16/20181/16/2018 3:58:00 PMPPASS
We are requesting a 1st floor kitchen wall rough-in and a 5th floor drop ceiling rough-in inspection for this afternoon. Our contact is Rick @ ###-####.
Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
512, 514, 516 thru 527, 529 thru 534 droplids and kitchen and bathroom walls and firelids rough in ok cover
ELE17-03957 Final1/16/20181/16/20181/16/2018 3:06:11 PMPPASS
###-####
Appliances hardwired, Final ok
ELE17-04264 Final1/16/20181/16/20181/16/2018 2:46:17 PMPPASS
Circuit is on roof. If you have any questions please give Paul a call.
Thank You!! Phone #: ###-#### Inspection requested via web by Paul Young Final ok
ELE17-04264 Electrical Rough-In1/16/20181/16/20181/16/2018 2:46:08 PMPPASS
Circuit is on roof. If you have any questions please give Paul a call.
Thank You!! Phone #: ###-#### Inspection requested via web by Paul Young
Circuit extension to relocate sign to south west corner. Rough in ok cover
ELE18-00184 Electrical Rough-In1/15/20181/16/20181/16/2018 2:11:18 PMPPASS
For access please call terry 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott
Remodel located at north east corner of building. New TI consists of waiting area, conference room and work room. Walls and hardlid rough in ok cover
ELE17-04065 Electrical Rough-In1/12/20181/16/20181/16/2018 1:09:47 PMAPASS
Wall Cover. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
Level 2 and 3 walls and hardlid rough in ok cover
ELE17-03957 Final1/15/20181/16/20181/16/2018 12:25:57 PMAFAIL
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
210.8(B)(2)- All receptacles installed in commercial kitchens shall have GFCI protection. 2 pole 40 amp for ovens and 2 pole 20 amp appliances.
ELE16-04017 Final1/16/20181/16/20181/16/2018 11:47:20 AMPPART
Final TOC Level 1 excludes stairwells, Elevator, and Generator Phone #: ###-#### Inspection requested via web by Debby Pierce
Level 1 of parking garage only partial final ok
ELE17-04186 Final1/16/20181/16/20181/16/2018 11:46:33 AMPPASS
S2 off of 13th street Phone #: ###-#### Inspection requested via web by Debby Pierce
Street light service final ok
ELE17-04187 Final1/16/20181/16/20181/16/2018 11:46:04 AMPPASS
S1 single metered Service 11th street Phone #: ###-#### Inspection requested via web by Debby Pierce
Street light service final ok
ELE17-03784 Final1/16/20181/16/20181/16/2018 11:44:05 AMPPART
TCO Temp final Boise Chamber Commerce. Verify GFI drinking fountain and front reception desk. Phone #: ###-#### Inspection requested via web by Debby Pierce
Water heater disconnect shall be below 6'7". Furniture shall be complete for final.
TCO partial final ok
ELE17-04186 Final1/15/20181/16/20181/16/2018 11:41:15 AMACANC
L1 Temp occupancy. Excludes the stairwells, elevator, and generator. Phone #: ###-#### Inspection requested via web by Debby Pierce
Wrong permit requested
ELE17-04117 Electrical Rough-In1/12/20181/16/20181/16/2018 10:42:21 AMAPASS
Ceiling Inspection

Contact Matt Bruns with any Questions Phone #: ###-#### Inspection requested via web by JENNY EMEL
Grid rough in ok cover
ELE18-00053 Final1/15/20181/16/20181/16/2018 10:20:07 AMAFAIL
Contact Andy Ward @ ###-#### with questions regarding work. Phone #: ###-#### Inspection requested via web by Megan Sheaman
BCC 4 05 32- Code violations not to be retained.
110.27- All wiring on back patio exposed to accidental contact. NM and knob and tube single conductors shall be protected from damage.
Verify circuit for baseboard heaters legal. Conduit and circuit for baseboard heaters dated 8/17/17 installed by others.
ELE17-04162 Permanent Service1/12/20181/16/20181/16/2018 9:13:24 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg
Chassis bond not done due to stack of wood at back location and AC circuits not supported to NEC requirements. Left red " Do Not Cover" on front right corner for do not skirt until inspected. p/s u/g rec ok
ELE18-00164 Permanent Service1/12/20181/16/20181/16/2018 9:08:01 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg
Underground covered prior to P/S inspection. p/s u/g rec ok
ELE17-04160 Final1/12/20181/16/20181/16/2018 9:07:18 AMANR
Phone #: ###-#### Inspection requested via web by jamie berg
Unable to final, no meter yet