Inspections for the day of: Wednesday, January 17, 2001.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM00-03851 Final1/16/20011/17/20011/17/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 01/16/2001 at 11:40:36. Contact: ###-####.
PLM00-04385 Final1/16/20011/17/20011/17/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 01/16/2001 at 13:18:13. Contact: ###-####.
PLM01-00125 Groundwork1/16/20011/17/20011/17/2001 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 01/16/2001 at 16:17:08. Contact: ###-####. this is for the rear restroom only the rest of this project will be done under another permit 1/17/2001 11:51:27 AM
PLM01-00129 Final1/17/20011/17/20011/17/2001 12:00:00 AMPFAIL
###-#### call first ammend permit to reflect interior fixtures, replumb bathroom waste so vents are above trap, 2 " min waste for waher, extendvent thru roof, pipe 3/4 from main shutoff to existing and a 3/4 branch to the water heater off that pick up the kitchen sink cold, 3/4 from the water heater to the existing with a 1/2" branch to the kitchen, lower kitchen sink trap to be below vent, pipe t&p drain to exterior with out traps 3/4", 3/4" valve required at the waterheater, plug sewer at manhole and test waste to floor level. water and sewer services installed without an ispection if the test holds I'll assume it's ok the water connection in the crawl seems ok and will assume the joint at the meter is the same. 1/17/2001 2:18:11 PM
PLM01-00133 Plumbing Rough-in1/17/20011/17/20011/17/2001 12:00:00 AMPPASS
###-####
PLM01-00134 Plumbing Rough-in1/17/20011/17/20011/17/2001 12:00:00 AMPPASS
###-####
PLM00-04403 Groundwork1/17/20011/17/20011/17/2001 12:00:00 AMPPART
###-####
PLM00-02653 Roof Drains1/12/20011/17/20011/17/2001 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 01/12/2001 at 15:34:52. Contact: ###-####. 2;30 1/16/2001 3:23:38 PM front part tested ok and stubs off mains in back ok need test on the rest of the rear section 1/17/2001 5:22:55 PM