ELE05-04252
| Electrical Rough-In | 1/16/2006 | 1/17/2006 | 1/17/2006 4:45:50 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 5:17:07 PM. Contact: ###-####. walls and ceilings ok
|
ELE06-00069
| Electrical Rough-In | 1/17/2006 | 1/17/2006 | 1/17/2006 4:12:50 PM | P | FAIL |
|
|
neal; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections not made nail plates and 11/4" cor. posted called
|
ELE05-04038
| Electrical Rough-In | 1/17/2006 | 1/17/2006 | 1/17/2006 3:48:52 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok
|
ELE05-04181
| Permanent Service | 1/16/2006 | 1/17/2006 | 1/17/2006 2:59:30 PM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 3:24:35 PM. Contact: ###-####. p/s u/g new ok
|
ELE05-04497
| Permanent Service | 1/17/2006 | 1/17/2006 | 1/17/2006 2:22:30 PM | P | PASS |
|
|
donna; Phone #: ###-#### Internet Inspection Request from: Barbara Moore p/s u/g new ok
|
ELE05-02785
| Final | 1/16/2006 | 1/17/2006 | 1/17/2006 1:52:28 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 9:19:30 PM. Contact: ###-####. cor. posted met owner secure boxes to structure and install all fixtures outside lights, correct wiring recept in garage, needs connectors for cables at ceiling fixtures in garage
|
ELE06-00157
| Temporary Service | 1/16/2006 | 1/17/2006 | 1/17/2006 1:30:11 PM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas cor. called use manufactures listed breakers only
|
ELE05-04293
| Rough-In Permanent Service | 1/16/2006 | 1/17/2006 | 1/17/2006 1:18:58 PM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 12:39:06 PM. Contact: ###-####. r/i ok p/s u/g new ok
|
ELE06-00015
| Rough-In Permanent Service | 1/16/2006 | 1/17/2006 | 1/17/2006 1:03:58 PM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 8:52:49 AM. Contact: ###-####. survey posted called grd boxes complete all makeup, #12 equip grd pigtail 2 gang box left of kit sink r/i ok p/s u/g new ok
|
ELE06-00143
| Temporary Service | 1/13/2006 | 1/17/2006 | 1/17/2006 11:13:54 AM | A | FAIL |
|
|
allen-- ###-#### shall not use pvc for support of mast and change or bond metal weatherhead called
|
ELE06-00147
| Electrical Rough-In | 1/17/2006 | 1/17/2006 | 1/17/2006 10:36:40 AM | P | DONE |
|
|
randy; Phone #: ###-#### Internet Inspection Request from: Barbara Moore was done in the AM
|
ELE05-04492
| Final | 1/16/2006 | 1/17/2006 | 1/17/2006 10:12:36 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 3:23:19 PM. Contact: ###-####. done by 370
|
ELE06-00105
| Permanent Service | 1/16/2006 | 1/17/2006 | 1/17/2006 9:42:42 AM | A | FAIL |
|
|
Please call 1/2 before for access - Tim ###-####; Phone #: ###-#### Internet Inspection Request from: Heather Packer see r/i notes
|
ELE06-00105
| Electrical Rough-In | 1/16/2006 | 1/17/2006 | 1/17/2006 9:42:02 AM | A | FAIL |
|
|
Please call 1/2 before for access - Tim ###-####; Phone #: ###-#### Internet Inspection Request from: Heather Packer cor. called 314.16 box fill 300.4 nail plates and 11/4", 250.66 all grds and bond #$, 250. 52(A)(1) or 104(A)(1) grd or bond water system 250.24 (A)(1) all grds and bonds shall terminate at neutral bus, 250.90,92 bond all raceways and nipples at p/s with #4, 250.56 needs 2 grd rods
|