ELE08-00130
| Permanent Service | 1/17/2008 | 1/17/2008 | 1/17/2008 4:21:06 PM | P | CANC |
|
|
Final on panel change. Phone #: ###-#### Internet Inspection Request from: Randy Fletcher see final
|
ELE08-00130
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 3:57:11 PM | P | PASS |
|
|
Final on panel change. Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok to final
|
ELE08-00072
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 3:27:27 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: David Seilheimer ok to final
|
ELE07-03820
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 2:40:28 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/16/2008 at 4:00:19 PM. Contact: ###-####. met contractor, gave correction notice, nec 410.30 (C) (2) c. cord connected luminaires shall use listed strain relief and canopy, rest of installation is ok
|
ELE07-03016
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 1:41:35 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham called, left correction notice, nec 352.30(A) rnc shall be supported within 3' of conduit termination, 404.9(A) switch faceplate shall seat against finished surface- upper bath, 406.4(E) receptacles shall not be installed in a face up position, 406.8(D) floor receptacles shall allow floor cleaning equipment to be operated without damage to the receptacle, 110.3(B) listed or labelled equipment shall be installed in accordance with instructions- jetted tub
|
ELE07-03564
| Electrical Rough-In | 1/17/2008 | 1/17/2008 | 1/17/2008 12:53:51 PM | P | PASS |
|
|
ceiling inspection Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover ceiling only
|
ELE08-00031
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 10:17:55 AM | A | PASS |
|
|
Plrease final. Electrician is kevin Brovetto @ ###-####. If door is not open just knock and someone will come to open it. Phone #: ###-#### Internet Inspection Request from: gary batten ok to final.
|
ELE08-00031
| Electrical Rough-In | 1/17/2008 | 1/17/2008 | 1/17/2008 10:10:57 AM | A | PASS |
|
|
Plrease final. Electrician is kevin Brovetto @ ###-####. If door is not open just knock and someone will come to open it. Phone #: ###-#### Internet Inspection Request from: gary batten ric ok
|
ELE08-00121
| Permanent Service | 1/16/2008 | 1/17/2008 | 1/17/2008 10:09:19 AM | A | CANC |
|
|
final on service upgrade, please call Jeff allan @ ###-#### and set time to be let in, he is the realtor with the key.any questions on service all George @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose see final
|
ELE08-00121
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 9:56:53 AM | A | PASS |
|
|
final on service upgrade, please call Jeff allan @ ###-#### and set time to be let in, he is the realtor with the key.any questions on service all George @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ok to final
|
ELE07-03835
| Electrical Rough-In | 1/17/2008 | 1/17/2008 | 1/17/2008 9:49:49 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/17/2008 at 6:25:19 AM. Contact: ###-####. called, left correction notice, nec 250.52(A)(1) shall provide connection for incoming water pipe, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(A)(2) shall provide receptacle in 2' wall in kitchen, 250.148(C) shall ground metal boxes, 314.20 boxes shall be flush with finished surface in walls of combustible material, NOTE: shall locate listing label for jetted tub
|
ELE08-00144
| Temporary Service | 1/16/2008 | 1/17/2008 | 1/17/2008 8:27:57 AM | A | PASS |
|
|
bill Phone #: t/s o/h n ok
|
ELE08-00130
| Permanent Service | 1/16/2008 | 1/17/2008 | 1/17/2008 6:52:57 AM | A | CANC |
|
|
Final on Permanent Service Phone #: ###-#### Internet Inspection Request from: Randy Fletcher Inspection cancelled from web by: Randy Fletcher
|