Inspections for the day of: Thursday, January 17, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00130 Permanent Service1/17/20081/17/20081/17/2008 4:21:06 PMPCANC
Final on panel change.
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher see final
ELE08-00130 Final1/17/20081/17/20081/17/2008 3:57:11 PMPPASS
Final on panel change.
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok to final
ELE08-00072 Final1/17/20081/17/20081/17/2008 3:27:27 PMPPASS
Phone #: ###-#### Internet Inspection Request from: David Seilheimer ok to final
ELE07-03820 Final1/16/20081/17/20081/17/2008 2:40:28 PMPFAIL
Scheduled by a contractor via Hello! on 1/16/2008 at 4:00:19 PM. Contact: ###-####. met contractor, gave correction notice, nec 410.30 (C) (2) c. cord connected luminaires shall use listed strain relief and canopy, rest of installation is ok
ELE07-03016 Final1/17/20081/17/20081/17/2008 1:41:35 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham called, left correction notice, nec 352.30(A) rnc shall be supported within 3' of conduit termination, 404.9(A) switch faceplate shall seat against finished surface- upper bath, 406.4(E) receptacles shall not be installed in a face up position, 406.8(D) floor receptacles shall allow floor cleaning equipment to be operated without damage to the receptacle, 110.3(B) listed or labelled equipment shall be installed in accordance with instructions- jetted tub
ELE07-03564 Electrical Rough-In1/17/20081/17/20081/17/2008 12:53:51 PMPPASS
ceiling inspection Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover ceiling only
ELE08-00031 Final1/16/20081/17/20081/17/2008 10:17:55 AMAPASS
Plrease final. Electrician is kevin Brovetto @ ###-####. If door is not open just knock and someone will come to open it. Phone #: ###-#### Internet Inspection Request from: gary batten ok to final.
ELE08-00031 Electrical Rough-In1/17/20081/17/20081/17/2008 10:10:57 AMAPASS
Plrease final. Electrician is kevin Brovetto @ ###-####. If door is not open just knock and someone will come to open it. Phone #: ###-#### Internet Inspection Request from: gary batten ric ok
ELE08-00121 Permanent Service1/16/20081/17/20081/17/2008 10:09:19 AMACANC
final on service upgrade, please call Jeff allan @ ###-#### and set time to be let in, he is the realtor with the key.any questions on service all George @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose see final
ELE08-00121 Final1/17/20081/17/20081/17/2008 9:56:53 AMAPASS
final on service upgrade, please call Jeff allan @ ###-#### and set time to be let in, he is the realtor with the key.any questions on service all George @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ok to final
ELE07-03835 Electrical Rough-In1/17/20081/17/20081/17/2008 9:49:49 AMAFAIL
Scheduled by a contractor via Hello! on 1/17/2008 at 6:25:19 AM. Contact: ###-####. called, left correction notice, nec 250.52(A)(1) shall provide connection for incoming water pipe, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(A)(2) shall provide receptacle in 2' wall in kitchen, 250.148(C) shall ground metal boxes, 314.20 boxes shall be flush with finished surface in walls of combustible material, NOTE: shall locate listing label for jetted tub
ELE08-00144 Temporary Service1/16/20081/17/20081/17/2008 8:27:57 AMAPASS
bill Phone #: t/s o/h n ok
ELE08-00130 Permanent Service1/16/20081/17/20081/17/2008 6:52:57 AMACANC
Final on Permanent Service Phone #: ###-#### Internet Inspection Request from: Randy Fletcher Inspection cancelled from web by: Randy Fletcher