MIS08-00006
| PLM-Conference | 1/16/2008 | 1/17/2008 | 1/18/2008 8:04:11 AM | P | FAIL |
|
|
Nail salon appears to not have previous Building permit or Certificate of Occupancy-plumbing permit will be required.
|
PLM07-03329
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 4:43:53 PM | P | PASS |
|
|
troy Phone #: ###-#### - please call for access
|
PLM07-03328
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 4:43:29 PM | P | PASS |
|
|
troy - please call for access Phone #: ###-####
|
PLM08-00136
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 4:01:14 PM | P | PART |
|
|
kirk Phone #: ###-####-need to delete bypass on water service & change rpba to dbca, need airgaps on indirect wastes, remove y brabch on mop sink, have pvb on lawn sprinklers tested & certified, will final when all plumbing work is complete.- temp final ok.
|
PLM08-00133
| Plumbing Rough-in | 1/17/2008 | 1/17/2008 | 1/17/2008 2:46:43 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Jeff Coate
|
PLM07-04035
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 2:38:59 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Jeff Coate
|
PLM06-04014
| Final | 1/17/2008 | 1/17/2008 | 1/17/2008 2:24:25 PM | P | PASS |
|
|
Final on Rough In only as per conversation with Eric Strole. Please call Everett with any questions ###-#### Phone #: ###-#### Internet Inspection Request from: Colleen Brown-this was for rough-in only. a new plumbing permit will need to be issued when building is to be finished.
|
PLM08-00137
| Water and/or Sewer | 1/17/2008 | 1/17/2008 | 1/17/2008 2:20:52 PM | P | PASS |
|
|
Heidi Phone #: ###-####
|
PLM07-03011
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 11:10:51 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: raul castanon-see permit plm07-03031
|
PLM07-03025
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 11:10:14 AM | A | FAIL |
|
|
CARLOS Phone #: ###-####-see permit plm07-03031
|
PLM07-03029
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 11:09:44 AM | A | FAIL |
|
|
CARLOS Phone #: ###-####-see permit plm07-03031
|
PLM07-03030
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 11:09:12 AM | A | FAIL |
|
|
CARLOS Phone #: ###-####-see permit plm07-03031
|
PLM07-03031
| Final | 1/16/2008 | 1/17/2008 | 1/17/2008 11:08:29 AM | A | FAIL |
|
|
CARLOS Phone #: ###-####-need thermal expantion, need base of stack & kitchen sink c/o uncovered, uncover sewer cleanouts, run pan drain, dbca needs tested & certified in building 11027, t & p's on outside building need 90's.talked with carlos, will call back in when coccections are complete.
|