Inspections for the day of: Friday, January 17, 2014.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDixie Fellows
TitleMEC-COM/RES INSPECTOR
Phone #794-6208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-00195 Rough-in1/16/20141/17/20141/17/2014 5:02:58 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Arcadio Martinez..r/i and 20lb gas ok
MEC14-00048 Final1/17/20141/17/20141/17/2014 3:59:28 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell
MEC13-00495 Final1/17/20141/17/20141/17/2014 3:58:29 PMPPASS
THIS WAS FOR GAS ONLY
MEC13-00495 Mec-Aging Inspection1/17/20141/17/20141/17/2014 3:57:38 PM PASS
THIS WAS FOR GAS ONLY
MEC12-03446 Mec-Aging Inspection1/17/20141/17/20141/17/2014 3:54:46 PM PEND
I CALLED NAT FOR THE 3RD TIME TO SCHEDULE THIS
MEC14-00082 Rough-in1/16/20141/17/20141/17/2014 3:52:07 PMPPASS
robin Phone #: ###-####..OK TO COVER CEILINGS
MEC14-00234 Final1/17/20141/17/20141/17/2014 2:20:19 PMPPASS
As early as possible, will need flue test witnessed. Thanks. Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-00211 Final1/17/20141/17/20141/17/2014 2:10:56 PMPPASS
dixie, call john ###-#### & he will let you in, he''s accross the street :) >> Inspection requested via web by Dustin Rich
MEC14-00178 Final1/16/20141/17/20141/17/2014 1:18:33 PMPPEND
Onsite contact: Pat Graves Phone #: ###-#### >> Inspection requested via web by Melissa Kaae...BILL HAD ME ASK PAT TO RESCHEDULE THIS FOR TUES. AS WE ARE SHORT HANDED
GCM14-00012 GCM-Rough In & Pressure Test1/16/20141/17/20141/17/2014 1:02:36 PMPFAIL
bonnie ###-####..NEED CUT-OUTS FOR CRAWL..NEED ACCESS TO F/P SPECS..20LB GAS OK..FLUE TESTS OK
MEC13-04398 Pressure Test1/17/20141/17/20141/17/2014 11:00:44 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Bryan Palmer..20LB GAS OK
MEC13-04398 Rough-in1/17/20141/17/20141/17/2014 11:00:02 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Bryan Palmer..R/I AND FLUE TEST OK..
MEC14-00143 Final1/16/20141/17/20141/17/2014 10:41:35 AMANH
Please call customer before showing up. Available between 9am - 12pm. Phone #: ###-#### >> Inspection requested via web by James Staley...CALLED AT 9:36..NO RETURN CALL AS OF 10:40
MEC13-04714 Final1/16/20141/17/20141/17/2014 10:40:31 AMANH
Please call Sharon at ###-#### Prior to inspection. After 9:30 Please. Phone #: ###-#### >> Inspection requested via web by Matt Sapp..NO RETURN CALL AS OF 10:20
MEC13-00469 Final1/16/20141/17/20141/17/2014 10:39:42 AMANH
Call Terry prior to arrival ###-####. Inspect 50 gal gas w/h installed on 1/27/13. Phone #: ###-#### >> Inspection requested via web by James Staley...LEFT A MESSAGE AT 9:36..NO RETURN CALL AS OF 10:38
GCM14-00018 GCM-Pressure Test1/16/20141/17/20141/17/2014 10:25:55 AMAFAIL
mIKE ###-####...WRONG GUAGE...NEED A 30LB
MEC13-03650 Pressure Test1/17/20141/17/20141/17/2014 9:35:40 AMAPASS
Radiant floor tubing pressure test, please call when on you way Phone #: ###-#### >> Inspection requested via web by Pat Falls..100lb test on hydronics ok
MEC14-00211 Final1/16/20141/17/20141/17/2014 8:44:10 AMAFAIL
8:30 meet owner ###-####...NEED 10X10 UPPER AND LOWER COMB AIR IN DOOR GOING INTO LAUNDRY ROOM