ELE17-00108
| Temporary Service | 1/17/2017 | 1/17/2017 | 1/17/2017 2:27:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE17-00109
| Temporary Service | 1/17/2017 | 1/17/2017 | 1/17/2017 2:26:47 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE17-00101
| Rough-In Permanent Service | 1/17/2017 | 1/17/2017 | 1/17/2017 1:47:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok p/s u/g n ok
|
ELE16-03475
| Final | 1/17/2017 | 1/17/2017 | 1/17/2017 1:32:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by ERIC CENTERS Final ok
|
ELE16-03148
| Final | 1/13/2017 | 1/17/2017 | 1/17/2017 1:31:48 PM | A | FAIL |
|
|
Gate access code - #2356. Phone #: ###-#### Inspection requested via web by Lars Johnson 408.36 D Back fed breakers shall be secured in place 110.26 A 1 Depth of work space shall be 36in. 110.26 A 1 Width of work space shall be 30in.
|
ELE16-03545
| Final | 1/17/2017 | 1/17/2017 | 1/17/2017 12:30:21 PM | P | PASS |
|
|
code 4224 any ? call bill ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE17-00061
| Rough-In Permanent Service | 1/16/2017 | 1/17/2017 | 1/17/2017 11:22:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok p/s u/g n ok
|
ELE17-00086
| Electrical Rough-In | 1/16/2017 | 1/17/2017 | 1/17/2017 10:59:50 AM | A | PASS |
|
|
There will be people there. If you have any questions please call Jake ###-#### Phone #: ###-#### Inspection requested via web by Clay Morgan Was told by general contractor City did not require building permit for job. Only Seperate PLM and ELE. Rough in ok Up Bath only
|
ELE17-00101
| Rough-In Permanent Service | 1/16/2017 | 1/17/2017 | 1/17/2017 10:35:48 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk 33in wall in master between entry door and bathroom door needs recep, Fire place NM cable needs suport and free conductor pushed in box, NM cable in garage pulled tight against Gang nail.
|
ELE17-00074
| Conference | 1/12/2017 | 1/17/2017 | 1/17/2017 9:59:47 AM | A | DONE |
|
|
John// please call ahead Phone #: ###-#### Talked about NM Cable support, Tamper resistant Receps, Wall space measurment, ground wire make up and inspection order
|
ELE17-00098
| Final | 1/16/2017 | 1/17/2017 | 1/17/2017 9:57:15 AM | A | PASS |
|
|
Call Steve when in route if possible. Obtain visitors pass from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
|
ELE17-00097
| Final | 1/16/2017 | 1/17/2017 | 1/17/2017 9:57:00 AM | A | PASS |
|
|
Call Steve when in route if possible. Obtain visitors pass from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
|
ELE15-04115
| Final | 1/16/2017 | 1/17/2017 | 1/17/2017 9:56:45 AM | A | PASS |
|
|
Call Steve when in route if possible. Obtain visitors pass from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
|
ELE16-01977
| Final | 1/16/2017 | 1/17/2017 | 1/17/2017 9:56:15 AM | A | PASS |
|
|
Call Steve when in route if possible. Obtain visitors pass from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
|
ELE16-02013
| Final | 1/16/2017 | 1/17/2017 | 1/17/2017 9:55:37 AM | A | PASS |
|
|
Call Steve when in route if possible. Obtain visitors pass from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
|
ELE17-00095
| Temporary Service | 1/16/2017 | 1/17/2017 | 1/16/2017 8:40:27 AM | P | CANC |
|
|
Please contact Todd ###-#### with any questions. Phone #: ###-#### >> Inspection requested via web by Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE17-00013
| Final | 1/13/2017 | 1/17/2017 | 1/13/2017 10:33:44 AM | A | CANC |
|
|
garage code 1001 Phone #: ###-#### >> Inspection requested via web by Charles Davis Inspection cancelled from web by: Charles Davis
|