Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS17-00013 ELE-Conference1/17/20171/17/20171/17/2017 3:00:40 PMPPASS
Possible work being done without permits (BLD, ELE, MEC and PLM)...

posted stop work order...electrical wiring done without permit, new windows being install without permits and plumbing work done without permits
ELE17-00075 Conference1/13/20171/17/20171/17/2017 2:14:12 PMPPASS
would like call ahead; judy Phone #: ###-####....

discussed repacing service mast for shop service....addition of ground rod, new grounding electrode conductor, clearance for side of shop, length of riser, wire size for overhead 200 amp service, addition of guide wire kit on riser, and max highth of riser above shop rough
ELE17-00111 Rough-In Permanent Service1/17/20171/17/20171/17/2017 1:05:17 PMPFAIL
Phone #: ###-#### Inspection requested via web by steve cooper....

1) can above sink cannot be wired off small appliance circuit or dishwasher disposal circuit
210.52(B)(2) 422.10

2) where NM cable is used the sheath shall extend not less than 1/4" inside the box 314.17(C).....throught house- mst bed switches, smoke detector in upstairs bedroom, and various other locations
ELE13-00382 ELE-Aging Inspection1/17/20171/17/20171/17/2017 11:41:36 AM DONE
notice posted at address that a final inspection needs requested or extension of permit is required
ELE16-01961 Permanent Service1/13/20171/17/20171/17/2017 11:09:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton....

p/s n ok
ELE16-01961 Electrical Rough-In1/13/20171/17/20171/17/2017 11:08:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...

rough in complete upstairs wall cover
ELE17-00088 Final1/16/20171/17/20171/17/2017 10:26:11 AMACANC
Temp pole Phone #: ###-#### Inspection requested via web by Kevin Burke...

needed temp service inspection
ELE17-00088 Temporary Service1/17/20171/17/20171/17/2017 10:25:22 AMAPASS
Temp pole Phone #: ###-#### Inspection requested via web by Kevin Burke..

t/s u/g n ok
ELE17-00087 Electrical Rough-In1/14/20171/17/20171/17/2017 10:11:47 AMAPASS
Inspection requested via web by David Seilheimer....

ok to cover
ELE16-02916 Final1/13/20171/17/20171/17/2017 9:46:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Thomas wilson...

final ok
ELE17-00078 Final1/13/20171/17/20171/17/2017 9:36:24 AMAPASS
Contact Miles for questions ###-#### Phone #: ###-#### Inspection requested via web by Sheri Berry....

replaced 6 existing lights and added 4...ok to final
ELE17-00057 Electrical Rough-In1/15/20171/17/20171/17/2017 9:19:52 AMAPASS
Please call Kyle Lott of Lott Electric INC, for any question. Have a very bless week! Phone #: ###-#### Inspection requested via web by Kyle Lott...

rough in wall cover only
ELE16-03280 Final1/16/20171/17/20171/17/2017 8:59:51 AMAFAIL
ANY QUESTIONS, PLEASE CALL TATE AT ###-#### Phone #: ###-#### Inspection requested via web by JENNY EMEL...

kitchen outlet reads hot neutral reverse

hood needs installation complete...exposed wires

outside sub panel needs labelling

breaker lockouts need installed on hard wired appliances

overcurrent device on heat pump is to large