Inspections for the day of: Wednesday, January 17, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00221 Permanent Service1/17/20181/17/20181/17/2018 2:38:01 PMPFAIL
This is a trailer home, located at space #3. Power was turned off by IPCO for unknown reasons, maybe non payment. Tree had grown in front of panel making it unable to open panel door and blocking meter. Tree has since been removed correcting clearance problems. I would like to meet the inspector on site and go through any non code compliance problems and get the service permitted for reenergizing by IPCO Phone #: ###-#### Inspection requested via web by Kurt Carlson 1 phase conductor load side came in contact with top of rigid pipe inside pedistal. No bushing was used for conduit, so it eventually wore through insulation.
ELE18-00103 Electrical Rough-In1/16/20181/17/20181/17/2018 2:12:00 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Scott Ok cover kitchen and bath.
ELE18-00225 Temporary Service1/17/20181/17/20181/17/2018 1:46:04 PMPPASS
community gate access 1599 Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE17-03200 Final1/17/20181/17/20181/17/2018 1:46:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Dean Gernaat Ok final.
ELE18-00115 Rough-In Permanent Service1/17/20181/17/20181/17/2018 1:16:43 PMPPASS
We would like a rough in for the interior and exterior walls. Soffits will be a separate rough in as the builder is constructing the WUI rated fire boxes for the recessed lights. Please call Eric with questions.
Thank you

Phone #: ###-#### Inspection requested via web by Eric Brown p/s u/g n ok. Ok cover except soffits. A soffit inspection will be required prior to cover.
ELE18-00021 Final1/16/20181/17/20181/17/2018 12:53:28 PMPPASS
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller Ok final. Gutter bonded, and receptacle within 6' removed and blanked.
ELE17-03805 Final1/16/20181/17/20181/17/2018 12:04:33 PMAPASS
access 6096 Phone #: ###-#### Inspection requested via web by David Nelson Ok final. Correction made.
ELE18-00160 Final1/17/20181/17/20181/17/2018 10:55:04 AMPPASS
We have rough in inspection this morning Phone #: ###-#### Inspection requested via web by Jesse Simpson Ok final.
ELE18-00182 Final1/17/20181/17/20181/17/2018 10:54:42 AMPPASS
Final inspection in conjunction with Altenergy final inspection

Thank you and have a great day! Phone #: ###-#### Inspection requested via web by JENNY EMEL Ok final. Looked at service when solar inspec was done.
ELE17-04218 Electrical Rough-In1/17/20181/17/20181/17/2018 10:39:06 AMAPASS
Down stairs rough-in only. Upstairs not ready Phone #: ###-#### Inspection requested via web by David McClellan Ok cover first floor only.
ELE18-00114 Electrical Rough-In1/16/20181/17/20181/17/2018 10:38:32 AMACANC
Phone #: ###-#### Inspection requested via web by Ryan Wake This was a duplicate inspection
ELE18-00114 Electrical Rough-In1/16/20181/17/20181/17/2018 10:37:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Ryan Wake Ok cover garage and space above.
ELE18-00160 Electrical Rough-In1/16/20181/17/20181/17/2018 9:33:38 AMAPASS
Jesse Phone #: ###-#### All components UL listed.
ELE18-00160 Final1/17/20181/17/20181/17/2018 9:33:20 AMPPASS
Ok final. All labels present as required by code.
ELE17-04184 Final1/16/20181/17/20181/17/2018 9:17:45 AMAPASS
Pls contact Spencer (Foreman) @ ###-#### or Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Christian Kilpatrick Ok final. Line side tap, disc within 10' code requirement.
ELE13-00238 ELE-Aging Inspection1/17/20181/17/20181/17/2018 8:29:34 AM DONE
Please schedule for a final inspection.