MEC19-00225
| Final | 1/17/2019 | 1/17/2019 | 1/17/2019 3:58:17 PM | P | PASS |
|
|
Please call contractor prior to inspection, homeowners do not speak English. Thank you Ted ###-#### Inspection requested via web by Margie Rowe- furnace a/c coil co ok
|
MEC19-00200
| Final | 1/14/2019 | 1/17/2019 | 1/17/2019 3:43:12 PM | P | CANC |
|
|
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- work not done- will install next week according to homeowner
|
MEC19-00094
| Rough-in | 1/17/2019 | 1/17/2019 | 1/17/2019 3:18:37 PM | P | FAIL |
|
|
Front door is open, worker in back yard, please call Val 30 minutes in advance when on way at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- range duct ran backwards- w/h b vent needs insulation shield in attic with fire stop installed with 1" clearance- need to seal end cap in chase second floor and finish tap to wall- need to seal r/a duct end cap 1st floor- all b vent needs 1" clearance to combustibles at roof level- need to add other(supply and R/A duct), dryer exhaust, range hood and 1 bath fan to permit and pay fees by final- correction notice posted inside front door left hand side on nail
|
MEC19-00250
| Final | 1/16/2019 | 1/17/2019 | 1/17/2019 2:24:07 PM | P | PASS |
|
|
INSTALLER RYAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace co ok
|
MEC19-00207
| Final | 1/16/2019 | 1/17/2019 | 1/17/2019 1:35:21 PM | P | PASS |
|
|
Please call Dave prior to arrival ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
|
MEC19-00169
| Final | 1/11/2019 | 1/17/2019 | 1/17/2019 11:56:05 AM | A | PASS |
|
|
Please call Jenny at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority- furnace co ok
|
MEC19-00234
| Pressure Test | 1/17/2019 | 1/17/2019 | 1/17/2019 11:43:04 AM | P | FAIL |
|
|
Before noon today or after 4 Phone #: ###-#### Inspection requested via web by Mary LaFayette- need 2 shutoff valves with open tee between it in crawl space- retest when completed- IRC 2417.1.4- no gas valve should have gas on one side and pressure on other
|
MEC18-05016
| Final | 1/16/2019 | 1/17/2019 | 1/17/2019 10:59:57 AM | A | PASS |
|
|
Please call Ted, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- 2 tube heaters exhaust fan evap cooler gas piping and regulators final ok- card signed
|
MEC19-00157
| Final | 1/16/2019 | 1/17/2019 | 1/17/2019 10:19:08 AM | A | PASS |
|
|
Homeowner will be home around 10:00am. If you could him when you head his way he said that would greatly appreciated. ###-#### (Tom) Phone #: ###-#### Inspection requested via web by Kim Evans- furnace a/c coil co ok
|
MEC19-00246
| Final | 1/16/2019 | 1/17/2019 | 1/17/2019 9:36:47 AM | A | PASS |
|
|
Call for access // Cameron Phone #: 20-###-####- bath fan final ok
|
MEC18-06005
| Final | 1/15/2019 | 1/17/2019 | 1/17/2019 9:12:58 AM | A | PASS |
|
|
Please call Tara in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
|
MEC18-05526
| Rough-in | 1/16/2019 | 1/17/2019 | 1/17/2019 8:40:55 AM | A | PART |
|
|
Bill Burch site contact Phone #: ###-#### Inspection requested via web by RM Mechanical- seal on duct work above 2 bathrooms east side ok- bathrooms are going to change to grid ceiling- need to provide return air path sheetrocked all the way to ceiling-
|
MEC17-03433
| Mec-Aging Inspection | 1/17/2019 | 1/17/2019 | 1/17/2019 8:10:36 AM | | FAIL |
|
|
contractor needs to call in final inspection- economizer needs installed
|
MEC17-03584
| Mec-Aging Inspection | 1/17/2019 | 1/17/2019 | 1/17/2019 8:09:34 AM | | CANC |
|
|
|
MEC17-03584
| DOC - Permit Expired | 1/17/2019 | 1/17/2019 | 1/17/2019 8:09:27 AM | A | PASS |
|
|
no calls
|
MEC17-04756
| Mec-Aging Inspection | 1/17/2019 | 1/17/2019 | 1/17/2019 8:08:26 AM | | FAIL |
|
|
contractor still needs to schedule final inspection
|