Inspections for the day of: Thursday, January 17, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMatt Wrobel
TitlePLM-INSPECTOR
Phone #803-4982
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-04069 PLM-Aging Inspection1/17/20191/17/20191/18/2019 9:37:33 AM PART
wip
PLM19-00230 Water Heater Final1/15/20191/17/20191/17/2019 3:58:00 PMPPASS
And water softener final-Bill Hawkes ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
PLM19-00211 Final1/16/20191/17/20191/17/2019 3:31:03 PMPPASS
Please call Dave prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
PLM19-00055 Water Heater Final1/17/20191/17/20191/17/2019 3:08:20 PMPPASS
Re-inspect after electrical work. Robert or Bonnie McCord ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
PLM19-00239 Final1/15/20191/17/20191/17/2019 2:48:42 PMPPASS
Please call Gary at ###-#### prior to arrival.
Thank you Phone #: ###-#### Inspection requested via web by chris mcdaniel
PLM18-04371 Final1/17/20191/17/20191/17/2019 2:13:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM18-02960 Final1/17/20191/17/20191/17/2019 1:51:21 PMPPASS
Job # 51763 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-05057 Final1/17/20191/17/20191/17/2019 1:24:28 PMPPASS
MARK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
PLM18-04257 Final1/15/20191/17/20191/17/2019 1:16:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by Marisa Hone
t&p cannot have a flex connector
electric water heater requires a disconnect switch or lockout breaker in panel
PLM18-05321 Final1/16/20191/17/20191/17/2019 11:53:14 AMAPASS
Jim Phone #: ###-####
PLM18-04742 Final1/15/20191/17/20191/17/2019 11:18:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone
PLM19-00252 Water and/or Sewer1/16/20191/17/20191/17/2019 10:33:46 AMAPASS
Phone #: ###-#### Inspection requested via web by keith braun
ok to cover
PLM19-00252 DOC - Permit Finaled1/17/20191/17/20191/17/2019 10:33:25 AMPPASS
PLM17-03152 PLM-Aging Inspection1/17/20191/17/20191/17/2019 10:14:20 AM PASS
PLM17-03152 DOC - Permit Finaled1/17/20191/17/20191/17/2019 10:14:12 AMPPASS
PLM17-03147 PLM-Aging Inspection1/17/20191/17/20191/17/2019 10:14:01 AM PASS
PLM17-03147 DOC - Permit Finaled1/17/20191/17/20191/17/2019 10:13:52 AMPPASS
PLM17-03966 Water Heater Final1/17/20191/17/20191/17/2019 10:12:54 AMAPASS
PLM17-03966 DOC - Permit Finaled1/17/20191/17/20191/17/2019 10:12:44 AMPPASS
PLM17-03966 PLM-Aging Inspection1/17/20191/17/20191/17/2019 10:12:33 AM PASS
PLM17-03966 Water Heater Final1/17/20191/17/20191/17/2019 10:12:20 AMACANC
PLM19-00206 Water Heater Final1/14/20191/17/20191/17/2019 10:05:21 AMAPASS
PLEASE CALL WHEN ON THE WAY. THANK YOU. Phone #: ###-#### Inspection requested via web by Chris Field
PLM18-03827 Final1/16/20191/17/20191/17/2019 9:33:53 AMAFAIL
Phone #: ###-#### Inspection requested via web by Brian Johansen
finish kitchen