BLD18-03625
| BLD-Framing/Rough-in | 1/15/2019 | 1/17/2019 | 1/17/2019 4:17:50 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complte lateral bracing on A3 and A4 trusses. Ok to insulate. Corection notice posted.
|
BLD18-03595
| BLD-Final | 1/16/2019 | 1/17/2019 | 1/17/2019 3:54:16 PM | P | PASS |
|
|
Shawn Phone #: ###-####
|
BLD18-03595
| DOC - Permit Finaled | 1/17/2019 | 1/17/2019 | 1/17/2019 3:54:07 PM | P | PASS |
|
|
|
BLD18-03063
| BLD-Framing/Rough-in | 1/17/2019 | 1/17/2019 | 1/17/2019 3:14:33 PM | P | NR |
|
|
Tiffany Phone #: ###-####. Needs MEPS. first.
|
BLD17-02871
| BLD-Wall cover | 1/17/2019 | 1/17/2019 | 1/17/2019 2:39:41 PM | P | PASS |
|
|
John Phone #: ###-####. New envelope compliance with the R30 at vaulted ceilings will be ok, 4% better than code. Spray foam insulation also ok per the ICC ESR report.
|
BLD18-03699
| BLD-Framing/Rough-in | 1/17/2019 | 1/17/2019 | 1/17/2019 2:13:14 PM | P | FAIL |
|
|
Shawn Phone #: ###-####. Complete lateral bracing on A03, A04,A05, A08 and A011 trusses. NAil BX1 and G2 trusses per the enginering. Roll block E4 trusses. Trusses in hangars on D4 truss not seated. All portal frames shall be nailed. Install all missed blocking and nail, install LIB. Provide the engineering for the tall walls in garage. Correction notice posted.
|
BLD18-04310
| BLD-Footing | 1/17/2019 | 1/17/2019 | 1/17/2019 1:06:35 PM | P | PASS |
|
|
Column pad footings for carport.
|
BLD18-02618
| BLD - Request for Extension | 1/11/2019 | 1/17/2019 | 1/17/2019 11:49:54 AM | A | PASS |
|
|
Bob Phone #: ###-####
|
BLD18-01121
| BLD-Footing | 1/15/2019 | 1/17/2019 | 1/17/2019 11:49:43 AM | A | PART |
|
|
Eric Phone #: ###-####. Footings ok. Per engineer, vertical reinforcement is equired.
|
BLD18-02176
| BLD-Footing | 1/16/2019 | 1/17/2019 | 1/17/2019 11:49:04 AM | A | DEFR |
|
|
Requesting early am thanks Phone #: ###-#### Inspection requested via web by Steve Mitchell. Special inspector on site.
|
BLD18-03249
| BLD-Concrete | 1/14/2019 | 1/17/2019 | 1/17/2019 11:12:12 AM | A | PART |
|
|
Phone #: 2088806738 >> Inspection requested via mobile web by Chet Clark. ICF permiter wall from top of footing to 10ft. 8 inch elev. Needs to tie verts in place and complet lintel steel.
|
BLD18-02386
| BLD-Final | 1/16/2019 | 1/17/2019 | 1/17/2019 10:41:56 AM | A | FAIL |
|
|
Dillon Phone #: ###-####. Temper window in master shower.
|
BLD18-04426
| BLD-Final | 1/16/2019 | 1/17/2019 | 1/17/2019 8:48:57 AM | A | PASS |
|
|
Josh-homeowner Phone #: ###-####
|
BLD18-04426