BLD04-02599
| BLD-Energy code compliance | 1/14/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | A | PASS |
|
|
rob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
MIS05-00008
| BLD-Final | 1/14/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | A | FAIL |
|
|
andy haskell at ###-#### pending fire fn -ater 9??? oc loadsign /main exit hardware/ele out side/foudation vent. 1/18/2005 9:38:37 AM
|
BLD04-02407
| BLD-Foundation | 1/14/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | A | CANC |
|
|
phillip; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called via contractor. 1/18/2005 2:56:35 PM
|
BLD04-03037
| BLD-Framing/Rough-in | 1/17/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Dennis Holmes need ele insp/ framing ok pending ele aproval/dual switching required per plan on lighting. 1/18/2005 2:31:19 PM
|
BLD04-02557
| BLD-Final | 1/11/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Dennis Holmes 1004.2.2 exit from rm's shall be ovious for exitting. 1/18/2005 2:34:06 PM
|
BLD04-02040
| BLD-Energy code compliance | 1/14/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/14/2005 at 7:19:45 AM. Contact: ###-####. justify r 21 in wall cavitys/rock fire wal/seal return airs/seal under tubs 1/18/2005 3:47:43 PM
|
MEC05-00168
| Rough-in | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | FAIL |
|
|
###-#### - joe gas test failled/pipe protection not per listing/4 dryer duct in 3 1/2 wall cavity/all duct out of bld.envlope req.r-8. 1/18/2005 4:39:13 PM
|
BLD04-02679
| BLD-Final | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 1/18/2005 at 8:37:49 AM. Contact: ###-####.
|
BLD04-01952
| BLD-Final | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | PASS |
|
|
rob; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD04-02977
| BLD-Footing | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 1/18/2005 at 9:28:27 AM. Contact: ###-####. wip set backs ok 1/18/2005 4:46:12 PM
|
BLD04-02751
| BLD-Wall cover | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Wayne Berry restore primary steel fireproofing at colm's and bar joist/firestop plm floor penatrations. pending other insp aprovals.1/18/2005 2:54:49 PM 1/18/2005 2:55:07 PM
|
BLD04-01436
| BLD-Framing/Rough-in | 1/18/2005 | 1/18/2005 | 1/18/2005 12:00:00 AM | P | PART |
|
|
justin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore need two joist hangers mlb south west 1 st floor support. ok to insulate. 1/18/2005 4:01:32 PM
|