Inspections for the day of: Wednesday, January 18, 2017.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00255 ELE-Aging Inspection1/18/20171/18/20171/19/2017 11:31:19 AM PASS
Doc final due to contractor doing job and no violations noted. Held for labels.
ELE12-01984 ELE-Aging Inspection1/18/20171/18/20171/19/2017 11:29:03 AM PASS
DOC final due to contractor doing job and no violations noted. Held for labels.
ELE17-00107 Final1/17/20171/18/20171/18/2017 3:42:09 PMPPASS
Only difference between rough in and final on this is installing a switch an 9 LED light trims Phone #: ###-#### Inspection requested via web by David McClellan
Final ok
ELE17-00037 Electrical Rough-In1/11/20171/18/20171/18/2017 2:25:17 PMADONE
Tom ###-#### Check temp wiring on club house to sign.
Temp wiring has been removed. Thank You
ELE17-00107 Electrical Rough-In1/17/20171/18/20171/18/2017 1:31:34 PMPPASS
New can lights in new "quiet room" in south end of gym. Removed fluorescents. Phone #: ###-#### Inspection requested via web by David McClellan
No new electrical in wall. Wall and ceiling rough in ok cover
ELE16-04063 Final1/18/20171/18/20171/18/2017 12:15:51 PMPPASS
Phone #: 2083425188 >> Inspection requested via mobile web by Chris Hopkins
Sign northwest corner. Disconnecting means and listing confirmed. Final ok
ELE16-04058 Electrical Rough-In1/17/20171/18/20171/18/2017 9:37:59 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
2nd floor sleeping room, wall fished, ceiling rough in ok cover
ELE16-03353 Final1/17/20171/18/20171/18/2017 9:30:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
Accelerator and controller listing confirmed. Final ok
ELE17-00113 Conference1/17/20171/18/20171/18/2017 8:26:11 AMADONE
Please call ahead for access - Matthew Phone #: ###-#### or Krista ###-####
Discussed addition of AC unit to east side of house. Water heater changing to gas. Will junction 30 amp circuit in basement and run out to east side. Basement ceiling open will call for final when complete all will be visible. Disconnecting means shall be with in sight and with in 50', service receptacle added with in 25' and shall be tamper and weather resistant type. Holes in boxes shall have abrasion protection and NM cable shall have supports not exceeding 4 1/2' and 12" of box.