Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-00057 Final1/10/20171/11/2017 A 
Phone #: ###-#### >> Inspection requested via web by Boe Jares
PLM15-03307 PLM-Aging Inspection1/18/20171/18/20171/25/2017 11:50:37 AM PEND
Spoke to the homeowner and contractor. Contractor to schedule
PLM16-02305 PLM-Aging Inspection1/18/20171/18/20171/19/2017 10:55:37 AM PASS
Ran to an area approved by Jim per Contractor
PLM17-00111 Final1/18/20171/18/20171/18/2017 2:24:01 PMPPASS
Would like call when on way. thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria 20# test ok
PLM17-00064 Plumbing Rough-in1/17/20171/18/20171/18/2017 12:20:00 PMAPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM17-00103 Water and/or Sewer1/17/20171/18/20171/18/2017 12:13:21 PMAFAIL
victor Phone #: ###-####
1. Install a tracer wire on the water service per ISPC 604.8.
2. Test the water service with 50 psi air or water.
3. Test the sewer with 5 psi air pressure or fill with water.
4. Install Schedule 40 pipe 3 feet from the house into the crawl space.
5. Install a schedule 40 wye branch fitting for the sewer cleanout. A santiary tee is not acceptable.
6. The gasketed 3034 sewer pipe is installed backwards. The female hub must be downstream of the male pipe. See drawing on the correction notice.
PLM17-00060 Water and/or Sewer1/16/20171/18/20171/18/2017 11:00:12 AMAPASS
Can we schedule a conference to discuss a few questions please? I am available on Wed any time. Thank you for your time. Aaron Johnson Phone #: ###-#### Inspection requested via web by Sarah Johnson