BLD16-01801
| BLD-Aging Inspection | 1/18/2017 | 1/18/2017 | 1/19/2017 9:50:27 AM | | PASS |
|
|
|
BLD16-03929
| BLD-Framing/Rough-in | 1/18/2017 | 1/18/2017 | 1/18/2017 3:35:07 PM | P | FAIL |
|
|
Larry Phone #: ###-####. Fireblock all fur downs and area next to fire place at ceiling level. Provide 2 studs under A0G1 2ply at interior wall. Noted majority of blocking missing for exterior wall bracing. Framers to review all truss engineering. Majority of bracing missing. Correction notice posted.
|
BLD16-04056
| BLD-Footing | 1/18/2017 | 1/18/2017 | 1/18/2017 2:54:28 PM | P | PART |
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro Phone #: ###-####
|
BLD16-03110
| BLD-Framing/Rough-in | 1/18/2017 | 1/18/2017 | 1/18/2017 2:40:51 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick. Fire block at concealed area at ceiling level adjacent to main entry door, provide floor joist hangar for floor joist by stairs, nail off simpson hangar upstairs. Ok to insualte.
|
BLD16-01726
| BLD-Final | 1/18/2017 | 1/18/2017 | 1/18/2017 2:12:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by joey benart
|
BLD16-01726
| DOC - Permit Finaled | 1/18/2017 | 1/18/2017 | 1/18/2017 2:11:43 PM | P | PASS |
|
|
|
BLD16-04362
| BLD-Framing/Rough-in | 1/17/2017 | 1/18/2017 | 1/18/2017 1:09:21 PM | P | PASS |
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez
|
BLD16-03144
| BLD-Final | 1/17/2017 | 1/18/2017 | 1/18/2017 10:28:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Weston Wagner
|
BLD16-03144
| DOC - Permit Finaled | 1/18/2017 | 1/18/2017 | 1/18/2017 10:28:45 AM | P | PASS |
|
|
|
BLD16-03443
| BLD-Wall Bracing | 1/17/2017 | 1/18/2017 | 1/18/2017 9:41:16 AM | A | NR |
|
|
Sam Phone #: ###-####. Provide the engineering. Noted several areas that were missed and exterior straps not fastened.
|
BLD16-02645
| BLD-Energy code compliance | 1/17/2017 | 1/18/2017 | 1/18/2017 9:00:47 AM | A | PASS |
|
|
Pat Phone #: ###-####
|
BLD16-02645
| BLD-Framing/Rough-in | 1/18/2017 | 1/18/2017 | 1/18/2017 9:00:35 AM | A | PASS |
|
|
Pat Phone #: ###-####
|
BLD16-04158
| BLD-Wall Bracing | 1/17/2017 | 1/18/2017 | 1/18/2017 8:39:54 AM | A | PART |
|
|
Sid Phone #: ###-####. block panel edges. ok to cover exterior.
|
BLD13-03497
| BLD-Conference | 1/17/2017 | 1/18/2017 | 1/18/2017 8:11:48 AM | A | DONE |
|
|
Greg-please call with a meet for access Phone #: ###-####. Spoke with Greg.He needs a fire/life/safety final and public works final prior to building final.
|