Inspections for the day of: Friday, January 18, 2019.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00020 Final1/17/20191/18/20191/18/2019 4:17:29 PMPPART
FINAL Phone #: ###-#### Inspection requested via web by Brandon Sorensen- condensate material needs to be plenum rated material above ceiling- temp occupancy ok
MEC19-00259 Final1/17/20191/18/20191/18/2019 3:45:49 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace a/c coil co ok
MEC18-05996 Pressure Test1/18/20191/18/20191/18/2019 3:17:57 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- 20lb gas pass- tagged gas line at meter location
MEC19-00236 Final1/18/20191/18/20191/18/2019 2:59:12 PMPCANC
Homeowner won''t be home after 3:00. So if its possible to be there before that, he would greatly appreciate it. Phone #: ###-#### Inspection requested via web by Kim Evans- electric furnAce a/c coil ok
MEC19-00243 Rough-in1/18/20191/18/20191/18/2019 2:25:22 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- gas test below 20psi- need to insulate supply duct in attic above master bedroom bare metal showing- need to seal all exhaust fan hook ups from fan to metal duct- need to seal range duct completely at ceiling level in kitchen open holes in square to round- condensate drain needs nail plate at ceiling in laundry- attic all good furnace and coil match man j- left correction notice front window
MEC19-00243 Pressure Test1/18/20191/18/20191/18/2019 2:22:13 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- gauge below 20psi
MEC18-05968 Final1/18/20191/18/20191/18/2019 1:47:09 PMPPASS
130 pm- call 30minutes in advanced- ###-####- furnace co ok
MEC19-00260 Final1/17/20191/18/20191/18/2019 1:22:52 PMAPASS
Home owner should be home. Call with questions. If you can not contact me you can call the installer. Elder at ###-####. Thank you. Jeremy Phone #: ###-#### Inspection requested via web by jeremy wanders- furnace a/c coil co ok
MEC19-00048 Final1/18/20191/18/20191/18/2019 1:12:16 PMPPASS
Please call Ted 30 minutes prior to inspection ,so he can meet you for the flu test. 2088605440. Thank you Inspection requested via web by Margie Rowe- furnace a/c coil co ok- 5lb flue test pass
MEC19-00079 Final1/18/20191/18/20191/18/2019 12:54:04 PMPPASS
MEC19-00079 Pressure Test1/18/20191/18/20191/18/2019 12:53:27 PMPPASS
LATE A.M. OR EARLY P.M. P/T
INSTALLER ANAS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass to range- co ok
MEC19-00234 Final1/18/20191/18/20191/18/2019 11:40:30 AMPPASS
MEC19-00234 Pressure Test1/17/20191/18/20191/18/2019 11:39:24 AMAPASS
Please inspect late AM. We will be there before 10 to do correction. Sharon Goltry ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- 20lb gas pass to range and dryer- double shut off with open tee installed- co ok
MEC19-00241 Rough-in1/17/20191/18/20191/18/2019 10:25:21 AMAPASS
Please call Dustin, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok- seal on duct ok- ok for grid recall in when registers are hooked up
MEC19-00132 Final1/17/20191/18/20191/18/2019 10:00:31 AMAPART
Phone #: ###-#### Inspection requested via web by Jeff Glynn- furnace a/c coil co ok- need to tie in condensate pump to furnace for emergency shutoff
MEC18-05084 Final1/17/20191/18/20191/18/2019 9:46:34 AMAPASS
Please call Aaron with any questions. Thanks! Phone #: ###-#### Inspection requested via web by john shay- duct blast test pass- final ok
MEC18-04945 Final1/16/20191/18/20191/18/2019 9:29:15 AMAPASS
Please call Brooke prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok
MEC18-05062 Final1/17/20191/18/20191/18/2019 9:12:20 AMAPASS
Brenda Phone #: ###-####- final ok
MEC18-05062 Rough-in1/17/20191/18/20191/18/2019 9:12:04 AMAPASS
Brenda Phone #: ###-####- R/I ok
MEC19-00158 Rough-in1/18/20191/18/20191/18/2019 8:57:55 AMAPASS
Duct Seal. Todd is your contact. call 20 minutes prior Phone #: ###-#### Inspection requested via web by Kim Adams- R/I ok- sesal on duct ok- ok to insulate- opk for grid will look at insulation at final- approved prints onsite
MEC18-05968 Final1/15/20191/18/20191/18/2019 8:25:01 AMANH
Homeowner requests early as possible. Please call when en route: Brian ###-#### Phone #: ###-#### Inspection requested via web by Michael Stimpson- called # listed no answer- went by rang doorbell then knocked no answer- no one home
MEC17-03630 Mec-Aging Inspection1/18/20191/18/20191/18/2019 8:00:39 AM CANC
MEC17-03630 DOC - Permit Expired1/18/20191/18/20191/18/2019 8:00:29 AMAPASS
work being done by contractors
MEC17-04771 Mec-Aging Inspection1/18/20191/18/20191/18/2019 7:59:24 AM FAIL
still needs scheduled
MEC19-00265 Final1/17/20191/18/20191/17/2019 2:58:45 PMACANC
Phone #: ###-#### >> Inspection requested via web by Nicholas Paige Inspection cancelled from web by: Nicholas Paige