Inspections for the day of: Friday, January 19, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-04644 Rough-In Permanent Service1/19/20071/19/20071/19/2007 4:01:38 PMPCANC
Scheduled by a contractor via Hello! on 1/19/2007 at 9:03:59 AM. Contact: ###-####. see ri only, offset still blocking meter and can't open door to operate breakers, called contr to call when fixed, WATCH OUT FOR DOG!!!!- IT CLIMBS FENCE OF PEN AND GETS LOOSE AND NOT HAPPY WITH VISITORS!!!
ELE06-04644 Electrical Rough-In1/19/20071/19/20071/19/2007 3:53:05 PMPPASS
Scheduled by a contractor via Hello! on 1/19/2007 at 9:03:59 AM. Contact: ###-####. ric ok
ELE06-03004 Final1/19/20071/19/20071/19/2007 3:39:17 PMPPASS
camille; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE07-00185 Electrical Rough-In1/19/20071/19/20071/19/2007 3:00:05 PMPPASS
Please contact Patrick, thank you Phone #: ###-#### ric ok
ELE06-02438 Permanent Service1/19/20071/19/20071/19/2007 2:42:17 PMPPASS
jim ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s u/g n ok
ELE07-00069 Final1/19/20071/19/20071/19/2007 1:38:30 PMPPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, told to mound up u/g to ensure full 18" depth for conduit, p/s o/h n ok
ELE07-00193 Temporary Service1/19/20071/19/20071/19/2007 1:09:52 PMPPASS
glen; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called, left survey, nec 312.5 all conductors entering enclosures shall have abrasion protection, t/s u/g n ok
ELE06-03004 Final1/18/20071/19/20071/19/2007 9:41:08 AMANH
butch ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr, left card
ELE05-04401 ELE-Aging Inspection1/19/20071/19/20071/19/2007 9:32:01 AM DONE
called to set up request for final injspection
ELE06-03550 Final1/19/20071/19/20071/19/2007 9:31:22 AMPPASS
jason; Phone #: ###-#### Internet Inspection Request from: Victoria Beall talked to contr, found labels for office furniture, ok to final, no card to sign
ELE05-03806 ELE-Aging Inspection1/19/20071/19/20071/19/2007 9:13:57 AM DONE
suc
ELE06-01275 Final1/17/20071/19/20071/19/2007 8:19:50 AMAPASS
8 am per Bob, Jim called this in; Phone #: ###-#### Internet Inspection Request from: Darla Downs met contr, ETL field evaluated x-ray, asked that copy be e-mailed to city attn 324, corrections made, ok to final, signed occ card
ELE06-02957 Final1/18/20071/19/20071/19/2007 7:47:17 AMAPART
dawn; Phone #: ###-#### Internet Inspection Request from: Victoria Beall talked to contr, signed t/o card, nec 210.62 at least 1 recpt shall be installed directly above a show window for each 12' or fraction there-of, BCC all make-up shall be done- outside lighting