ELE15-04134
| Electrical Rough-In | 1/18/2016 | 1/19/2016 | 1/19/2016 3:06:39 PM | P | PASS |
|
|
Call George before hand at ###-#### Phone #: ###-#### Inspection requested via web by Shannon Wall verfied ul listing and disc. also scope of work
|
ELE16-00055
| Electrical Rough-In | 1/19/2016 | 1/19/2016 | 1/19/2016 2:47:49 PM | P | FAIL |
|
|
Call George before hand so he can meet you on the job site. ###-#### Phone #: ###-#### Inspection requested via web by Shannon building permit not payed
|
ELE15-03403
| Final | 1/19/2016 | 1/19/2016 | 1/19/2016 2:36:07 PM | P | CANC |
|
|
If possible make it the last inspection of the day, they would like a final and we have a few more things to wrap up thank you Phone #: ###-#### Inspection requested via web by Brad Baker contractor not ready
|
ELE16-00168
| Electrical Rough-In | 1/19/2016 | 1/19/2016 | 1/19/2016 1:16:38 PM | P | PASS |
|
|
Inspection requested via web by Larry Richardson master closet ok cover
|
ELE16-00148
| Electrical Rough-In | 1/18/2016 | 1/19/2016 | 1/19/2016 12:55:14 PM | P | PASS |
|
|
Unable to install meter base, will schedule service inspection on a later date. Thank You Phone #: ###-#### Inspection requested via web by Robert Schroder contrator will call for service inspection on a later date rough-in ok cover
|
ELE15-01131
| Final | 1/19/2016 | 1/19/2016 | 1/19/2016 12:38:54 PM | P | PASS |
|
|
Final for exterior and garage. Please call Eric @ ###-#### to schedule entrance to site. Thank You Phone #: ###-#### Inspection requested via web by Eric Brown exterior final ok
|
ELE15-03640
| Final | 1/19/2016 | 1/19/2016 | 1/19/2016 12:18:30 PM | P | PASS |
|
|
Please call ahead for access - Will Phone #: ###-#### panel wall ok cover
|
ELE15-02860
| Final | 1/18/2016 | 1/19/2016 | 1/19/2016 12:18:18 PM | P | FAIL |
|
|
Inspection requested via web by Lynn Solmon 210.8(5) unfinished basements shall have GFCI protection 406.6 cover plates required 314.22 extension required for light in mechanical room
|
ELE14-01817
| Final | 1/14/2016 | 1/19/2016 | 1/19/2016 11:18:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kendra Lanham master bath final ok
|
ELE16-00065
| Final | 1/15/2016 | 1/19/2016 | 1/19/2016 11:05:08 AM | A | PASS |
|
|
call for access; Eric Phone #: ###-#### final ok
|
ELE16-00149
| Electrical Rough-In | 1/19/2016 | 1/19/2016 | 1/19/2016 10:36:33 AM | A | PASS |
|
|
Mother-in-law quarters in the back Phone #: ###-#### Inspection requested via web by Greg Idsinga mother in law quarters ok cover
|
ELE16-00141
| Electrical Rough-In | 1/15/2016 | 1/19/2016 | 1/19/2016 10:09:24 AM | A | FAIL |
|
|
Tom// please call before Phone #: ###-#### 210.52 (g) branch circuit suppling garages shall not supply any outside receptacles
|
ELE16-00161
| Rough-In Permanent Service | 1/19/2016 | 1/19/2016 | 1/19/2016 9:43:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI rough-in ok cover p/s u/g n ok
|
ELE16-00136
| Rough-In Permanent Service | 1/18/2016 | 1/19/2016 | 1/19/2016 9:19:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov rough-in ok cover p/s u/g n ok 4-meters
|
ELE15-03590
| Final | 1/18/2016 | 1/19/2016 | 1/19/2016 9:19:01 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 408.4 field indentififcation required (house panel) 200.11Polarity of connections (kitchen GFCI) unit 201/ arc fault breaker shall be firmly mounted unit 201
|