ELE17-03456
| Final | 1/18/2018 | 1/19/2018 | 1/19/2018 2:02:14 PM | P | FAIL |
|
|
garage code 1905 Phone #: ###-#### Inspection requested via web by kevin blackmon 210.8A7 receps within 6ft of sink shall be GFCI protected. 210.52C1 Receps shall be installed so that no point measured along wall line is more than 24in from recep. 314.20 Boxes set back more than 1/4in shall have extension ring
|
ELE18-00237
| Electrical Rough-In | 1/17/2018 | 1/19/2018 | 1/19/2018 12:44:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jay Hutchison Disc. Shall be provided as per 225.31 before final rough in ok
|
ELE17-04373
| Final | 1/16/2018 | 1/19/2018 | 1/19/2018 11:35:22 AM | A | PASS |
|
|
Call Jeff on your way to meet you there ###-####. If you have any questions please feel free to contact Jake ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clay Morgan final ok
|
ELE18-00106
| Rough-In Permanent Service | 1/18/2018 | 1/19/2018 | 1/19/2018 10:04:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|
ELE18-00235
| Electrical Rough-In | 1/17/2018 | 1/19/2018 | 1/19/2018 10:03:45 AM | A | PASS |
|
|
Please call prior to arrival. Phone #: ###-#### Inspection requested via web by Patrick Paz Master closet cans, master bath only ok to cover
|
ELE18-00251
| Temporary Service | 1/18/2018 | 1/19/2018 | 1/19/2018 9:20:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by danny perrine t/s u/g n ok
|
ELE17-03876
| Electrical Rough-In | 1/18/2018 | 1/19/2018 | 1/19/2018 9:05:52 AM | A | PASS |
|
|
Kitchen rough in Kaz Phone #: ###-#### Corrections made kitchen, Pantry only ok to cover
|
ELE13-02969
| Final | 1/19/2018 | 1/19/2018 | 1/19/2018 8:59:17 AM | P | PASS |
|
|
No work was done final ok
|