ELE05-04401
| Rough-In Permanent Service | 1/20/2006 | 1/20/2006 | 1/20/2006 3:50:36 PM | P | FAIL |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong cor. fee due posted called more violations created from 1st correction posted, 250.102(C) shall size bond jumper to 250.66, 408.36(F) back fed device clip 120/230 V panel, 300.4 (F) bushings for 4 and larger, 300.10 tighten grd choke fittings, nipples from LBs shall have locknuts both sides of cabinet and be made up tight, everything is loose, 110.12(A) seal all unused KOs
|
ELE05-03215
| Rough-In Permanent Service | 1/20/2006 | 1/20/2006 | 1/20/2006 2:43:51 PM | P | PART |
|
|
'Cover Inspection' contact Dave at ###-#### if questions .. ; Phone #: ###-#### Internet Inspection Request from: Cathy Felin walls and har ceilings in offices and locker bathrm area, walls in showrm ok
|
ELE06-00218
| Temporary Service | 1/20/2006 | 1/20/2006 | 1/20/2006 1:56:57 PM | P | PASS |
|
|
Joe-Journeyman; Phone #: ###-#### Internet Inspection Request from: William Zerfas t/s u/g new ok
|
ELE06-00176
| Temporary Service | 1/20/2006 | 1/20/2006 | 1/20/2006 1:11:44 PM | P | PASS |
|
|
ANY QUESTIONS PLEASE CALL ED SCHALLOCK; Phone #: ###-#### Internet Inspection Request from: Jeff Radford t/s u/g new ok
|
ELE06-00196
| Electrical Rough-In | 1/20/2006 | 1/20/2006 | 1/20/2006 10:32:37 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/20/2006 at 7:14:54 AM. Contact: ###-####.walla ceilings ok
|
ELE06-00118
| Electrical Rough-In | 1/20/2006 | 1/20/2006 | 1/20/2006 10:31:52 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/20/2006 at 7:13:56 AM. Contact: ###-####. walls ceilings ok
|
ELE06-00199
| Electrical Rough-In | 1/20/2006 | 1/20/2006 | 1/20/2006 9:59:49 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: joe wheeler walls ok
|
ELE05-04497
| Electrical Rough-In | 1/19/2006 | 1/20/2006 | 1/20/2006 9:33:35 AM | A | PASS |
|
|
Donna -- ceiling inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth ok
|
ELE05-04047
| Final | 1/19/2006 | 1/20/2006 | 1/20/2006 9:05:38 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/19/2006 at 3:36:56 PM. Contact: ###-####. cor. fee due posted called 314.17 needs connectors at bell boxes for cables, 225.30 detached garage shall have only one branch circuit or feeder, 225.31,32 provide disconnect at required location
|
ELE06-00218
| Temporary Service | 1/19/2006 | 1/20/2006 | 1/20/2006 8:29:39 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: William Zerfas cor. called 312.5 conn for GEC, 250.24 terminate GEC at neutral
|
ELE05-03136
| Final | 1/19/2006 | 1/20/2006 | 1/20/2006 8:10:13 AM | A | FAIL |
|
|
garage code is 1234 Internet Inspection Request from: Cevyn Recla correction not made still needs clearence, or remove wiring coat closet under stairs called
|
ELE05-04541
| Conference | 1/20/2006 | 1/20/2006 | 1/20/2006 12:00:00 AM | P | DONE |
|
|
ok
|
ELE06-00223
| Rough-In Permanent Service | 1/19/2006 | 1/20/2006 | 1/19/2006 2:26:47 PM | A | PASS |
|
|
darrell ###-#### r/i ok p/s u/g new ok
|