Inspections for the day of: Wednesday, January 20, 2010.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02005 ELE-Aging Inspection1/20/20101/20/20101/22/2010 11:22:16 AM DONE
looked at sign, see final
ELE08-02110 ELE-Aging Inspection1/20/20101/20/20101/21/2010 10:07:28 AM DONE
no activity, see doc expire
ELE08-02213 ELE-Aging Inspection1/20/20101/20/20101/21/2010 9:34:56 AM DONE
no activity, see doc expire
ELE09-02337 Electrical Rough-In1/20/20101/20/20101/20/2010 4:07:06 PMPPART
Please inspect the Underground for cover. Wireman on-site is Pat at ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Clint Tate ok to cover u/g anop
ELE08-02058 DOC - Permit Expired1/20/20101/20/20101/20/2010 3:38:15 PMPPASS
no activity, ok to doc expire
ELE08-02045 DOC - Permit Expired1/20/20101/20/20101/20/2010 3:11:31 PMPPASS
no activity, ok to doc expire
ELE08-01472 DOC - Permit Expired1/20/20101/20/20101/20/2010 2:24:37 PMPPASS
no activity, ok to doc expire
ELE08-02000 Final1/20/20101/20/20101/20/2010 1:26:21 PMPPASS
ok to final
ELE09-01649 Final1/19/20101/20/20101/20/2010 12:36:11 PMPPASS
Brian Phone #: ###-#### ok to final, no esc this project
ELE10-00107 Electrical Rough-In1/20/20101/20/20101/20/2010 12:35:10 PMPPASS
Phone #: ###-#### Internet Inspection Request from: TRAVIS WARFIELD ric ok, no esc this project
ELE10-00101 Final1/19/20101/20/20101/20/2010 10:43:14 AMAPASS
Jake-Please call at least 30 mins prior to inspection Phone #: ###-#### ok to final, no esc this project
ELE10-00065 Final1/19/20101/20/20101/20/2010 10:22:26 AMAPART
Contact: Tom Betty, please call before going so Tom can meet you there Phone #: ###-#### Internet Inspection Request from: Deb Gooden electrical ok to final after bld in place, no esc this project
GCE10-00003 GCE-Final1/19/20101/20/20101/20/2010 9:28:43 AMAPASS
Contact Andy ok to final, no esc this project
GCE10-00004 GCE-Rough-In Permanent Service1/19/20101/20/20101/20/2010 8:47:04 AMAFAIL
Contact Brian @ ###-####Owner Apryl @###-#### Ext 101 called, left correction notice, NEC 250.52(A)(5) shall use 5/8" ground rods, 250.56 shall augment ground rod, 312.5 shall provide abrasion protection, 3120.16 shall provide overcurrent protection per code, 406.8(B) receptacle shall be weather resistant listed type, 210.8 receptacle shall be gfci type, 250.119 shall identify gec per code