ELE13-00542
| ELE-Aging Inspection | 1/20/2015 | 1/20/2015 | 1/27/2015 11:22:53 AM | | DONE |
|
|
Drove by for sale sign posted. Will check to see if open permit is issue with sale.
|
ELE15-00096
| Final | 1/16/2015 | 1/20/2015 | 1/20/2015 2:21:26 PM | P | PASS |
|
|
Diana Phone #: ###-#### Final ok
|
ELE14-02675
| Permanent Service | 1/20/2015 | 1/20/2015 | 1/20/2015 1:44:08 PM | P | PASS |
|
|
Toby is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen Metal water pipe bond to be done when pipe present. p/s u/g n ok
|
ELE14-03399
| Electrical Rough-In | 1/19/2015 | 1/20/2015 | 1/20/2015 1:11:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jay Symonds Garage rough in ok cover
|
ELE14-03238
| Rough-In Permanent Service | 1/20/2015 | 1/20/2015 | 1/20/2015 12:49:54 PM | P | PASS |
|
|
Radiant floor heat in bathroom only.
Thank you, Phone #: ###-#### Inspection requested via web by Rhonda Zamagni Floor heat rough in ok cover
|
ELE14-02943
| Final | 1/20/2015 | 1/20/2015 | 1/20/2015 12:18:53 PM | A | PASS |
|
|
Josh is contact thank you Phone #: ###-#### Inspection requested via web by Chris Chesnut No record of floor heat rough in, listing confirmed. At time of final lights in master closet and light over bath tub ok. Final ok
|
ELE15-00113
| Electrical Rough-In | 1/16/2015 | 1/20/2015 | 1/20/2015 11:40:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Entrance on back south east corner. Reception and break room wall rough in ok cover
|
ELE14-02675
| Permanent Service | 1/19/2015 | 1/20/2015 | 1/20/2015 11:22:54 AM | A | FAIL |
|
|
Toby is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen 250.24(A)(1)- The grounding electrode conductor connection shall be made at the same terminal or bus to which the grounded conductor is connected. 250.50- All available grounding electrodes shal be used to form grounding electrode system.
|
ELE15-00125
| Electrical Rough-In | 1/19/2015 | 1/20/2015 | 1/20/2015 9:56:40 AM | A | PASS |
|
|
Wall cover in floral area. Dan Lowry is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen 3, 1/2 walls to south of old location rough in ok cover
|
ELE14-03277
| Rough-In Permanent Service | 1/19/2015 | 1/20/2015 | 1/20/2015 9:33:37 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer Wrong permit for request, refer to ele15-00126
|
ELE15-00126
| Permanent Service | 1/20/2015 | 1/20/2015 | 1/20/2015 9:33:20 AM | P | FAIL |
|
|
310.15(B)(7)- In no case shall the service entrance conductors be sized less than 83% of the service rating. 125 amp x 83%= 103.75 amps. Table 310.15(B)(16)- 75* #2 minimum size required.
|
ELE15-00126
| Electrical Rough-In | 1/20/2015 | 1/20/2015 | 1/20/2015 9:25:32 AM | P | PASS |
|
|
Rough in ok cover
|
ELE15-00126
| Rough-In Permanent Service | 1/20/2015 | 1/20/2015 | 1/20/2015 9:24:49 AM | P | CANC |
|
|
See rough in
|
ELE15-00046
| Rough-In Permanent Service | 1/16/2015 | 1/20/2015 | 1/20/2015 8:41:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Rohl Rough in ok cover p/s u/g n ok
|