ELE14-00146
| Conference | 1/17/2014 | 1/21/2014 | 1/21/2014 5:27:21 PM | P | DONE |
|
|
Mike Phone #: ###-#### Talked with homeowner about garage and game room addition. Discussed electrical requirements for exsisting hot tub.
|
ELE13-03387
| Electrical Rough-In | 1/20/2014 | 1/21/2014 | 1/21/2014 3:35:47 PM | A | FAIL |
|
|
Toby. Ceiling cover. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy NEC 800.25 Cables shall be supported off ceiling grid. Abandoned cable shall be removed. Cables for future use shall be tagged and indentified.
|
ELE14-00143
| Final | 1/17/2014 | 1/21/2014 | 1/21/2014 2:42:48 PM | A | PASS |
|
|
robert Phone #: ###-#### final ok
|
ELE13-02933
| Final | 1/16/2014 | 1/21/2014 | 1/21/2014 2:24:57 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Bryan Atkins Replaced like for like flood fixture on sign, final ok
|
ELE14-00167
| Electrical Rough-In | 1/21/2014 | 1/21/2014 | 1/21/2014 2:20:01 PM | P | PASS |
|
|
Dan-Please call prior to insepction Phone #: ###-#### rough-in ok cover walls
|
ELE13-02604
| Final | 1/17/2014 | 1/21/2014 | 1/21/2014 1:38:14 PM | A | NH |
|
|
Contact is Justin Metcalf. Please call when you are headed to the project for this final inspection. Thank you so much and have a great day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw NO access
|
ELE13-02890
| Final | 1/21/2014 | 1/21/2014 | 1/21/2014 1:24:50 PM | A | PASS |
|
|
Electrical Final Phone #: ###-#### >> Inspection requested via web by Clay Jackson final ok
|
ELE14-00148
| Electrical Rough-In | 1/20/2014 | 1/21/2014 | 1/21/2014 12:47:09 PM | A | PASS |
|
|
Electrical rough in 3 dedicated printer circus installed in wall 2 up in the ceiling ready to be dropped into the point of sales and one outlet in newly framed wall that''s waiting for sheetrock. call Mickey Johnson at ###-####9 to unlock door he has several stores down at the UPS Store Phone #: ###-#### >> Inspection requested via web by shane miller rough-in ok cover wall
|
ELE14-00089
| Rough-In Permanent Service | 1/19/2014 | 1/21/2014 | 1/21/2014 12:29:10 PM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 320.23 Guard strip in attic, shall also be nailed inplace. NEC 312.5(C) Where cables are used, each cable shall be secured to the cabnet NEC 334.30 NM cable shall be sercured within 12 in. of every outlet box, junction box, cabnet
|
ELE12-01444
| Final | 1/17/2014 | 1/21/2014 | 1/21/2014 10:12:15 AM | A | FAIL |
|
|
Cathy Fangerow (homeowner) Phone #: ###-#### Upstairs master bathroom Exsisting luminaire over shower stall missing cover. NEC 410.10(A) All luminaires installed in wet locations shall be listed and marked suitable for wet locations and shall have GFCI protection
|
ELE13-03490
| Final | 1/18/2014 | 1/21/2014 | 1/21/2014 9:38:44 AM | A | PASS |
|
|
lock box code is 1359 Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack final ok
|
ELE13-03490
| Electrical Rough-In | 1/18/2014 | 1/21/2014 | 1/21/2014 9:37:42 AM | A | PASS |
|
|
grid ceiling, lock box code is 1359 Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack rough-in ok cover ceiling grid
|
ELE13-03351
| Electrical Rough-In | 1/20/2014 | 1/21/2014 | 1/21/2014 9:27:31 AM | A | PASS |
|
|
Please call when on way ###-####. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan rough-in ok cover dettached shop
|
ELE14-00145
| Electrical Rough-In | 1/17/2014 | 1/21/2014 | 1/21/2014 8:39:19 AM | A | PASS |
|
|
inspection of new room in basement please call Vance @ ###-#### for access Phone #: ###-#### >> Inspection requested via web by Andy Rose rough-in ok cover
|
ELE14-00135
| Temporary Service | 1/17/2014 | 1/21/2014 | 1/21/2014 8:15:00 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Heath Thomas t/s u/g n ok
|
ELE14-00134
| Temporary Service | 1/17/2014 | 1/21/2014 | 1/21/2014 8:11:56 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Heath Thomas t/s u/g n ok
|