Inspections for the day of: Tuesday, January 21, 2014.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEvan Jenkins
TitleEROSION CONTROL MANAGER
Phone #794-3958
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-01346 Site Preparation1/21/20141/21/20141/21/2014 4:19:04 PMPPART
Luke Phone #: ###-####
Trench in waddles per manufactures spec.
Install construction entrance per our (my discussion with Luke via cell) prior to my arrival for the site prep inspection. Luke ensured me that the construction entrance would be complete prior to my arrival, but the excavator was already digging down to elevation for foundation. I gave luke my last verbal warning for all Site Prep Inspections: "No Earth Disturbance to take place prior to an Approved Site Prep Insepction". This goes with ALL Syringa Construction Projects. Luke to call PDS to schedual a reinspection for tomorrow morning. If corrections not address/fixed, stop work order will be issued. Reinspection fee will be assessed.
ESC13-00112 Aging Inspection1/21/20141/21/20141/21/2014 11:12:16 AM PASS
No ESC Issues at this time
Work in Progress
ESC13-00254 Aging Inspection1/21/20141/21/20141/21/2014 10:54:05 AM PART
Post Constructin Signage
Other previous ESC Issues have been corrected
ESC13-00249 Aging Inspection1/21/20141/21/20141/21/2014 10:39:00 AM DONE
see final. project has been done since last spring 2013
ESC13-00249 DOC - Permit Finaled1/21/20141/21/20141/21/2014 10:38:25 AMPPASS
Complete
Called RP and the pool was installed last spring. Informed him he needs to call PDS to schedual site final inspections for other open permits
ESC13-01127 BMP Violation1/21/20141/21/20141/21/2014 10:00:42 AMAFAIL
ACHD Stormwater Complaint
Correction Notice Posted: ACHD Issued a Notice of Violation:
-Install Construction Entrance, Install Perimeter BMP's, Sweep ACHD ROW and Sidewalk, Remove Porta-Pot from ACHD Sidwalk (Causing Obstruction), Cleanup scattered Debris throughout Project.
Attempted to call RP Rob Haddock 2869456, got ahold of secretary. Disclosed to her for Rob to call me back ASAP and address multiple BMP violations and have the issues address/fixed by 1-22-14 by 12:00pm or a Stop Work Order shall be issued along with potential Civil Penalties. She stated she will get people out righ away to begin cleanup and address BMP violations. Will reinspect tomorrow 1-22-14 at 12:00pm to ensure contractor is back in compliance
ESC13-00685 Aging Inspection1/21/20141/21/20141/21/2014 9:05:22 AM DONE
see final
ESC13-00685 DOC - Permit Finaled1/21/20141/21/20141/21/2014 9:04:56 AMPPASS
Complete
No ESC Issues
RP stated he is in the process to call in final inspections on the rest of the permits