ELE06-01438
| ELE-Aging Inspection | 1/22/2007 | 1/22/2007 | 1/23/2007 4:46:03 PM | | PART |
|
|
called wsuc
|
ELE05-03669
| ELE-Aging Inspection | 1/22/2007 | 1/22/2007 | 1/23/2007 8:07:38 AM | | PART |
|
|
wsuc
|
ELE07-00066
| Permanent Service | 1/22/2007 | 1/22/2007 | 1/22/2007 3:36:54 PM | P | FAIL |
|
|
Phone #: ###-#### corr. called 310.15 (B)(2)(a) table derate conductors, 312.5(C) shall insyall cables as code noted states ,or install conductors in pvc to a Jbox under house then splice to romex, 250.148 splice and grd equip grd in jbox in house (old panel used as jbox), 408.8 panel schedule shall be specific location purpose and use
|
ELE06-04433
| Electrical Rough-In | 1/19/2007 | 1/22/2007 | 1/22/2007 2:18:59 PM | P | PART |
|
|
CONTACT: JASON MARTINEAU - CEILING INSPECTION PLEASE Phone #: ###-#### ok anop
|
ELE06-01341
| Electrical Rough-In | 1/22/2007 | 1/22/2007 | 1/22/2007 1:45:09 PM | P | PART |
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Victoria Beall u/g across parking lot ok
|
ELE06-03684
| Final | 1/22/2007 | 1/22/2007 | 1/22/2007 1:24:07 PM | P | PASS |
|
|
linda - call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
|
ELE06-03513
| Final | 1/22/2007 | 1/22/2007 | 1/22/2007 11:58:05 AM | P | PASS |
|
|
Morgan ###-#### final ok
|
ELE06-04306
| Final | 1/18/2007 | 1/22/2007 | 1/22/2007 10:37:48 AM | A | PASS |
|
|
READY FOR REINSPECTION. HOMEOWNERS WILL BE HOME MONDAY JANUARY 22, A.M. THANKS Phone #: ###-#### ok
|
ELE06-03345
| Final | 1/21/2007 | 1/22/2007 | 1/22/2007 10:37:26 AM | A | PASS |
|
|
ok
|
ELE07-00151
| Final | 1/19/2007 | 1/22/2007 | 1/22/2007 9:49:07 AM | A | PASS |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall lights ok
|
ELE06-03647
| Final | 1/22/2007 | 1/22/2007 | 1/22/2007 9:20:19 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/22/2007 at 6:42:12 AM. ok
|
ELE07-00094
| Permanent Service | 1/21/2007 | 1/22/2007 | 1/22/2007 8:58:58 AM | A | FAIL |
|
|
Phone #: ###-#### corr. called 250.24(A)(1)terminate all GEC to neutral bus, 250.58 all grd electrodes shall tie togrther to form a common grd electrode system, ID meters
|
ELE07-00161
| Rough-In Permanent Service | 1/19/2007 | 1/22/2007 | 1/22/2007 8:13:12 AM | A | PART |
|
|
Requesting a uffer inspection. Phone #: ###-#### ok
|