ESC06-00968
| Aging Inspection | 1/22/2009 | 1/22/2009 | 1/23/2009 2:26:04 PM | | CANC |
|
|
|
ELE08-03258
| Final | 1/22/2009 | 1/22/2009 | 1/22/2009 3:42:00 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/22/2009 at 11:13:32 AM. Contact: ###-####. called corr needs recpt 25ft of a/c
|
ELE08-03259
| Final | 1/22/2009 | 1/22/2009 | 1/22/2009 3:41:28 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/22/2009 at 11:12:10 AM. Contact: ###-####. called corr remove low voltage from below P/S, gfci right of range bad, outside back gfci loose
|
ELE08-02731
| Electrical Rough-In | 1/22/2009 | 1/22/2009 | 1/22/2009 2:42:09 PM | P | NR |
|
|
Afternoon Jack, We are ready for a ceiling cover inspection, if you have any questions please call. Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig needs support wires for cables
|
ELE08-02167
| Electrical Rough-In | 1/21/2009 | 1/22/2009 | 1/22/2009 2:01:44 PM | P | PART |
|
|
andy Phone #: ###-#### east end walls ok
|
ELE08-02905
| Electrical Rough-In | 1/22/2009 | 1/22/2009 | 1/22/2009 1:02:23 PM | P | PART |
|
|
Please provide Area A and B inspection. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean grid ceilings anop areas A & B
|
ELE09-00121
| Electrical Rough-In | 1/22/2009 | 1/22/2009 | 1/22/2009 12:18:19 PM | P | PASS |
|
|
pat Phone #: ###-#### ok fan in bathroom
|
ELE09-00121
| Final | 1/22/2009 | 1/22/2009 | 1/22/2009 12:17:55 PM | P | PASS |
|
|
pat Phone #: ###-#### ok
|
ELE09-00017
| Electrical Rough-In | 1/22/2009 | 1/22/2009 | 1/22/2009 10:55:25 AM | A | FAIL |
|
|
when you get to the property, give me a call to let you in as the building is locked during the day. Thank you Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman needs to attach ele to bld
|
ELE08-03205
| Final | 1/21/2009 | 1/22/2009 | 1/22/2009 10:32:43 AM | A | PASS |
|
|
chris Phone #: ###-#### ok card signed
|
ELE09-00044
| Rough-In Permanent Service | 1/21/2009 | 1/22/2009 | 1/22/2009 9:53:01 AM | A | FAIL |
|
|
Joe Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt corr for high and low voltage wiring, called, needs connectors at outside pancake boxes where 1/2" ko is used, also connectors or bushings ay low voltage cabinet 110.14 splices loose wrong tool used for grd wire crimp sleeves 334.30 and 314.17(C) shall staple romex within 8", or 12" of boxes, 300.4 nail plaetes, note u/g too bomb shelter covered before inspection, outside back recept not wired, provide access at electrode connection
|
ELE08-00875
| Electrical Rough-In | 1/21/2009 | 1/22/2009 | 1/22/2009 8:42:16 AM | A | PART |
|
|
MORGAN CEILING COVER Phone #: ###-#### Internet Inspection Request from: Sean DeLacy 1st and 2nd floor hallways (shell and core)
|