Inspections for the day of: Wednesday, January 22, 2014.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03463 Electrical Rough-In1/22/20141/22/20141/22/2014 4:48:29 PMPPASS
mike Phone #: ###-#### Rough in ok cover
ELE09-02323 ELE-Aging Inspection1/22/20141/22/20141/22/2014 4:12:46 PM DONE
Drove by. Still under construction
GCE14-00009 GCE-Permanent Service1/21/20141/22/20141/22/2014 3:21:03 PMAPASS
Ryan ###-#### Call at noon p/s o/h rec ok
ELE13-01291 Final1/21/20141/22/20141/22/2014 2:45:40 PMPCANC
Please contact Rob Crook for access Phone #: ###-#### >> Inspection requested via web by Tina Payne Needed inspection at 5310 w. state. Wrong permit requested
ELE13-02501 Final1/22/20141/22/20141/22/2014 2:44:40 PMPPASS
For service on and in pre fab building. Final ok
ELE14-00182 Permanent Service1/22/20141/22/20141/22/2014 1:42:49 PMPPASS
This Service Is Located On Garage, We Are relocating The Service From The House. The Power Lines Are real Close To New Structure And We Need To get Power Swung To Complete Service Change. Thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett p/s o/h n ok
ELE13-02947 Final1/22/20141/22/20141/22/2014 1:00:07 PMPNR
please call ahead for access - james Phone #: ###-#### Garage at rough in stage final not ready.
ELE13-02947 Permanent Service1/22/20141/22/20141/22/2014 12:32:00 PMPPASS
please call ahead for access - james Phone #: ###-#### p/s o/h n ok
ELE13-02947 Electrical Rough-In1/22/20141/22/20141/22/2014 12:31:12 PMPPASS
please call ahead for access - james Phone #: ###-#### Garage rough in ok cover
ELE13-02783 Electrical Rough-In1/21/20141/22/20141/22/2014 11:15:06 AMACANC
Contact: Jeremy Thornock Phone #: ###-#### >> Inspection requested via web by Deb Gooden This permit requested due to finalled 15th floor permit finalled be mistake. Reopened
ELE13-02654 Final1/22/20141/22/20141/22/2014 10:51:40 AMAPART
Danny on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen 210.8- Bar receptical outlets on back side of bar located with in 6' of sink shall have GFCI protection. Lighting control panel circuits shall be identified. Kitchen only ok to occupy
ELE13-02469 Electrical Rough-In1/22/20141/22/20141/22/2014 10:45:43 AMPFAIL
300.11- All cables shall be supported independant of grid including data cables
ELE13-02057 Electrical Rough-In1/21/20141/22/20141/22/2014 9:41:47 AMAFAIL
3rd floor corridor. Levi is on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen 3rd floor ceiling assembly- 300.11(1&2)- Wiring located in cavity shall not be supported by ceiling assembly or its support system unless manufacturers instruction state other wise. Contact # disconnected
ELE14-00175 Conference1/21/20141/22/20141/22/2014 9:04:35 AMADONE
Rocky-Please call prior to insepction Phone #: ###-#### Discussed overhead service entrance conductors over roof which is 4/12 or steeper 3' clearance required.
ELE13-02755 Final1/21/20141/22/20141/22/2014 8:39:46 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Final ok
ELE13-02034 Final1/21/20141/22/20141/22/2014 8:37:33 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Chris Chesnut Final ok
GCE14-00008 GCE-Rough-In Permanent Service1/21/20141/22/20141/22/2014 8:20:09 AMANR
Terry ###-#### Wiring not complete