Inspections for the day of: Thursday, January 22, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01321 ELE-Aging Inspection1/22/20151/22/20151/23/2015 10:42:15 AM DONE
left correction notice on site 1-23-15 10:45 am
ELE10-02116 ELE-Aging Inspection1/22/20151/22/20151/23/2015 9:48:00 AM DONE
left message on Julie cell phone, nobody home at site.
ELE14-01926 Final1/22/20151/22/20151/22/2015 1:28:35 PMPPASS
Call Builder Zac ###-#### for access please. Phone #: ###-#### Inspection requested via web by Paula Gratiot
corrections made/ Final OK
ELE14-03383 Electrical Rough-In1/22/20151/22/20151/22/2015 1:07:46 PMPNR
Floor heat cover. Contact is Buster Phone #: ###-#### Inspection requested via web by Buster Bowen
caught the tile guy installing this in AM, stopped his work, came back for PM inspection, no access and no answer on phone.
ELE14-03117 Final1/22/20151/22/20151/22/2015 12:57:44 PMPPASS
CODE 1234 ANY ? CALL TOM ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn
Final OK
ELE14-03043 Electrical Rough-In1/22/20151/22/20151/22/2015 12:38:28 PMPPASS
Ceiling rough-in inspection - Contact is Alan Krishnek.###-#### Phone #: ###-#### Inspection requested via web by Scott Campbell
ceiling OK to cover, bathrooms floor 1 and 2
ELE15-00133 Temporary Service1/21/20151/22/20151/22/2015 12:15:28 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
TS, UG, N, OK
ELE15-00134 Temporary Service1/21/20151/22/20151/22/2015 12:01:57 PMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
TS, UG, N< OK
ELE14-01765 Final1/21/20151/22/20151/22/2015 11:34:28 AMAPASS
Ryan is contact Phone #: ###-#### Inspection requested via web by Chris Chesnut
Final OK
ELE14-03326 Final1/21/20151/22/20151/22/2015 11:03:38 AMAPASS
please contact Jamie with any electrical questions at ###-####. thank you Phone #: ###-#### Inspection requested via web by Lori Stout
Final OK
ELE14-03515 Electrical Rough-In1/22/20151/22/20151/22/2015 10:19:32 AMAPASS
WUII fire domes over can lights Phone #: ###-#### Inspection requested via web by kendall bender
Fire barrier installed for soffit cans, ok to cover
ELE11-00300 ELE-Aging Inspection1/22/20151/22/20151/22/2015 10:07:48 AM DONE
spoke to owner, and checked site, still under construction, plans to finish in next few months.
ELE15-00158 Permanent Service1/21/20151/22/20151/22/2015 9:58:37 AMACANC
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering.
The ACCESS CODE is 4077 Phone #: ###-#### Inspection requested via web by Stephen Kren
250.53 Grounding electrode system required with supplemental grounding electrode
334.30 NM shall be secured within 12 inches of boxes
250.64 grounding electrodes shal be continyuous or a permitted splicing method used
200.7 ungrounded conductors shall be permanently re-identified
250.104 metal piping shall be bonded to service enclosure
300.4 cables through bored holes shall be protected
210.4 multi wire branch circuits shall have handle ties, or you can remove splices in neutrals and land them to the bar
open boxes shall be closed, disconnected cables shall be properly terminated or removed
bundling of cables not allowed
210.8.5 GFI protection required unfinished basement
cables and boxes are hanging directly from ceiling, need repaired
BCC 4.5.32 Known code violations not to be retained
ELE15-00053 Permanent Service1/22/20151/22/20151/22/2015 9:19:36 AMAPASS
New 200 amp overhead service. Phone #: ###-#### Inspection requested via web by Eric Brown
PS, OH, N, OK
ELE14-02346 Final1/22/20151/22/20151/22/2015 8:50:23 AMPPASS
Permit for spa has been created, final for home OK
ELE15-00159 Electrical Rough-In1/21/20151/22/20151/22/2015 8:46:48 AMAPASS
Underground and bonding. Phone #: ###-#### Inspection requested via web by Kotton Corder
Spa is low volt lighting and controls, largest circuit out to spa is 120 and GFI according to contractor, conduits stop underground at small a/c unit, underground OK to cover, bonding OK