Inspections for the day of: Tuesday, January 22, 2019.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00118 Rough-in1/21/20191/22/20191/22/2019 4:04:23 PMPFAIL
Please stipulate fireplace not approved for cover until selection has been made by builder. Property is accessible all day, please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs
- gas pressure test fail gauge was under 20lb
- dryer vent needs to be installed in a 2x6 wall
- need ladder to access attic where furnace is located
MEC19-00300 Rough-in1/21/20191/22/20191/22/2019 3:35:27 PMPPASS
call Manny 20 min advance
signal inside building is spotty
job should be ready for inspection around 2pm Phone #: ###-#### Inspection requested via web by Manuel Canto
- R/I ok
MEC18-05034 Final1/22/20191/22/20191/22/2019 3:08:14 PMPPASS
Kevin Phone #: ###-####
- final ok
MEC19-00213 Rough-in1/21/20191/22/20191/22/2019 2:22:45 PMPNR
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
- check 5lb flue pressure test on R/I
MEC19-00213 Pressure Test1/21/20191/22/20191/22/2019 2:22:12 PMPPASS
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
- 20lb gas pressure test ok
- will check 5lb flue on R/I
MEC19-00313 Pressure Test1/22/20191/22/20191/22/2019 2:06:21 PMPPASS
Call Darin Monroe before arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- need to add gas fireplace to permit before final
- 20lb gas pressure test ok
- need to prove existing gas line size will provide enough gas for all appliances
MEC19-00117 Final1/17/20191/22/20191/22/2019 1:48:29 PMPCANC
Please call on way: Dan ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- should have been a R/I for the range vent
MEC19-00117 Rough-in1/22/20191/22/20191/22/2019 1:47:47 PMPPASS
Please call on way: Dan ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- this inspection should have been a R/I
- dryer and range hood ok
- schedule final when range is installed
MEC19-00151 DOC - Permit Finaled1/22/20191/22/20191/22/2019 1:28:09 PMPPASS
MEC19-00151 Pressure Test1/15/20191/22/20191/22/2019 1:27:47 PMPPASS
INSTALLER ANAS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 20lb pressure test ok for range
MEC19-00051 Final1/18/20191/22/20191/22/2019 11:56:17 AMAPASS
David Phone #: ###-####
- furnace only co ok
MEC19-00242 Final1/18/20191/22/20191/22/2019 11:40:19 AMAPASS
Client has from 10:00 am to 2PM available for inspection. Please call prior to arrival at ###-####
Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace ac coil co ok
MEC19-00175 Final1/17/20191/22/20191/22/2019 11:39:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone
- furnace only co ok
MEC19-00299 Rough-in1/21/20191/22/20191/22/2019 11:12:01 AMAPART
Phone #: ###-#### Inspection requested via web by Rene Neumeyer
- R/I ok
- need to see non combustible material installed around fireplace top and sides
MEC18-05521 Rough-in1/21/20191/22/20191/22/2019 10:50:09 AMAPASS
Inspection requested via web by Mike Almanza
- fireplace R/I ok
MEC18-05143 Final1/18/20191/22/20191/22/2019 10:40:46 AMAPASS
Majia Phone #: ###-####
- final ok
MEC18-05441 Final1/18/20191/22/20191/22/2019 10:29:56 AMAPASS
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
- final ok
MEC19-00216 Final1/18/20191/22/20191/22/2019 10:03:01 AMACANC
Call first so we can meet you on site and let you in. Phone #: ###-#### Inspection requested via web by Doug Turner
- needed to be a pressure test so gas company could set meter
- electrical permit needs to be pulled for mini split
- pressure test passed and tagged meter
MEC18-04889 Final1/18/20191/22/20191/22/2019 10:00:52 AMAPASS
Key will be in outlet in front of store // Paul Phone #: ###-####
- final ok
MEC18-04886 Final1/18/20191/22/20191/22/2019 10:00:02 AMAPASS
Key will be in the outlets in front of the store // Paul Phone #: ###-####
- final ok
MEC17-03846 Final1/21/20191/22/20191/22/2019 9:42:59 AMAPASS
CALL ###-#### FOR ACCESS ; REMOVE OUTDOOR HOOD FROM INSPECTION Phone #: ###-#### Inspection requested via web by Aaron Alandt
- final ok
MEC18-04393 Final1/18/20191/22/20191/22/2019 9:42:40 AMAPASS
David Phone #: ###-####
MEC18-06136 Rough-in1/18/20191/22/20191/22/2019 9:15:03 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- b vent upstairs needs 1" clearances to flex
- insulation shield has gaps needs to be solid no insulation should be able to touch vent
- dryer vent upstairs needs to be in a 2x6 wall
- need to see a 5lb flue test
MEC18-06136 Pressure Test1/18/20191/22/20191/22/2019 9:12:49 AMAPART
Phone #: ###-#### Inspection requested via web by Gary Reeves
- 20lb gas pressure test ok
- need to see 5lb flue test
MEC19-00216 Pressure Test1/22/20191/22/20191/22/2019 8:50:21 AMAPASS
Call first so we can meet you on site and let you in. Phone #: ###-#### Inspection requested via web by Doug Turner
- 20lb gas pressure test ok for new meter being set- tagged meter bar
MEC18-05324 Final1/17/20191/22/20191/22/2019 8:30:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Dave Sorensen
- final ok
MEC17-02415 Mec-Aging Inspection1/22/20191/22/20191/22/2019 8:09:04 AM FAIL
MEC18-00299 Mec-Aging Inspection1/22/20191/22/20191/22/2019 8:03:40 AM FAIL
need to scheduled inspection