ELE05-02060
| ELE-Aging Inspection | 1/23/2006 | 1/23/2006 | 1/27/2006 8:29:00 AM | | NR |
|
|
called contractor suc
|
ELE06-00241
| Electrical Rough-In | 1/20/2006 | 1/23/2006 | 1/23/2006 4:15:59 PM | P | PASS |
|
|
Bob ###-#### switch in wall at entrance ceiling ok
|
ELE03-02903
| ELE-Aging Inspection | 1/23/2006 | 1/23/2006 | 1/23/2006 3:22:59 PM | | NR |
|
|
suc
|
ELE05-01974
| ELE-Aging Inspection | 1/23/2006 | 1/23/2006 | 1/23/2006 3:00:59 PM | | NR |
|
|
suc
|
ELE05-04589
| Electrical Rough-In | 1/20/2006 | 1/23/2006 | 1/23/2006 3:00:42 PM | P | PART |
|
|
Ed; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong walls and hard lids ok
|
ELE06-00257
| Rough-In Permanent Service | 1/23/2006 | 1/23/2006 | 1/23/2006 1:14:59 PM | P | PASS |
|
|
Mark ###-#### P/S U/G N Ok R/I Ok no approved print check for required outlets on final
|
ELE05-03887
| Final | 1/20/2006 | 1/23/2006 | 1/23/2006 11:31:30 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 1/20/2006 at 11:15:47 AM. Contact: ###-####. no card
|
ELE05-02578
| Final | 1/20/2006 | 1/23/2006 | 1/23/2006 10:58:41 AM | A | NH |
|
|
final on kitchen remodel Internet Inspection Request from: Andy Rose no answer to door
|
ELE06-00237
| Final | 1/20/2006 | 1/23/2006 | 1/23/2006 10:58:04 AM | A | PASS |
|
|
circuit for computer and heater Internet Inspection Request from: Andy Rose
|
ELE06-00193
| Final | 1/20/2006 | 1/23/2006 | 1/23/2006 10:09:18 AM | A | FAIL |
|
|
need inspection on hot tub and recessed can lighting. Call homeowner @###-#### to set time so she can be there to let you in Internet Inspection Request from: Andy Rose 400.8 Uses Not Permitted. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for the following: Cord not permitted for direct burial. 300.5 Underground Installations (A) Minimum Cover Requirements Direct-buried cable or conduit or other raceways shall be installed to meet the minimum cover requirements of Table 300.5. 358.10 Uses Permitted (B) Corrosion Protection Ferrous or nonferrous EMT, elbows, couplings, and fittings shall be permitted to be installed in concrete, in direct contact with the earth, or in areas subject to severe corrosive influences where protected by corrosion protection and judged suitable for the condition. 680.22 Area Lighting, Receptacles, and Equipment (A) Receptacles (2) Other Receptacles, Location Other receptacles shall be not less than 3.0 m (10 ft) from the inside walls of a pool. (5) GFCI Protection All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground-fault circuit interrupter. Receptacles that supply pool pump motors and that are rated 15 or 20 amperes, 125 volts through 250 volts, single phase, shall be provided with GFCI protection. 680.8 Overhead Conductor Clearances Overhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water.
|
ELE06-00247
| Electrical Rough-In | 1/21/2006 | 1/23/2006 | 1/23/2006 10:00:16 AM | A | PART |
|
|
Please call Mike at ###-#### to arrange entrance to building prior to inspection. Internet Inspection Request from: Steve Craig east bathroom ok
|
ELE06-00211
| Temporary Service | 1/20/2006 | 1/23/2006 | 1/23/2006 9:59:46 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot T/S U/G Ok
|
ELE05-04203
| Final | 1/20/2006 | 1/23/2006 | 1/23/2006 8:13:03 AM | A | PASS |
|
|
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
ELE05-04589
| Electrical Rough-In | 1/20/2006 | 1/23/2006 | 1/20/2006 12:00:00 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 1/20/2006 at 1:05:06 PM. Contact: ###-####
1-20-06 needed PM insp/eus
|