Inspections for the day of: Monday, January 23, 2012.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorClint A Smith
TitleEROSION CONTROL INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC10-00778 General Inspection1/23/20121/23/20121/23/2012 4:12:27 PM FAIL
Verbal to RP:
Install additional sediment protection along the bottom of the top soil stockpile on the canal side. Maintain the perimeter sediment barriers along the Boise River side of the project. There are two areas where the sediment barrier is either being consumed by the stockpile and another part where there is a gap between the wattles. Will follow up on 1/27/2011 am.
ESC11-00816 General Inspection1/20/20121/23/20121/23/2012 2:06:19 PMACANC
ESC11-00681 BMP Violation1/20/20121/23/20121/23/2012 2:06:08 PMAPART
Contractor install perventitive measures. And cleanedup all of the sediment and debris from the hard surfaces.
ESC11-00709 General Inspection1/20/20121/23/20121/23/2012 10:41:40 AMAPASS
ESC11-00055 General Inspection1/23/20121/23/20121/23/2012 10:41:34 AM PASS
Waiting on stabiliztionto acheive
ESC09-00352 BMP Violation1/20/20121/23/20121/23/2012 10:41:10 AMAPART
Will have the rock check dam back inplace by 1/24/2012
ESC11-00884 General Inspection1/23/20121/23/20121/23/2012 9:58:26 AM PASS
ESC11-00009 General Inspection1/23/20121/23/20121/23/2012 9:51:14 AM PASS
ESC11-00415 BMP Violation1/20/20121/23/20121/23/2012 9:48:33 AMAFAIL
Final Notice:
CLean up all mortar residual surrounding the batch mixers and the washout the containerize or remove from the project. When equipment can access the back section of the project, They must relocate the batch mixers into a contained area that is lined with a 10mil or greater plastic. Also no more vehicle access is allowed to the back portion of the project area until the time being that a stabilized construction exit is install per industry standards.
Will re-inspect on 1/24/2012 am for attempts to achieve compliance.
ESC10-00918 General Inspection1/23/20121/23/20121/23/2012 8:28:40 AM PASS
ESC09-00507 General Inspection1/23/20121/23/20121/23/2012 8:18:22 AM PASS