Inspections for the day of: Wednesday, January 23, 2013.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01599 ELE-Aging Inspection1/23/20131/23/20131/25/2013 2:52:18 PM DONE
still under construction
ELE11-01483 ELE-Aging Inspection1/23/20131/23/20131/24/2013 2:57:37 PM PASS
see final
ELE13-00130 Electrical Rough-In1/23/20131/23/20131/23/2013 3:26:38 PMPPASS
late pm please//Virgil Phone #: ###-#### rough-in ok cover under ground with at least 2 in. of concrete
ELE12-00984 Final1/16/20131/23/20131/23/2013 2:38:57 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot final ok No C of O card on site
ELE13-00137 Electrical Rough-In1/22/20131/23/20131/23/2013 2:01:03 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by fred lopez NEC 330.(B)Shall be protected from physical damage, 1 1/4 from edge of framing member NEC 334.30 shall secure MC cable within 12 in. of box.
ELE12-02998 Electrical Rough-In1/23/20131/23/20131/23/2013 1:05:32 PMPNR
Call Dave for access instructions. Phone #: ###-#### >> Inspection requested via web by David Mackey Not ready
ELE13-00136 Final1/22/20131/23/20131/23/2013 12:35:21 PMPNH
Phone #: ###-#### >> Inspection requested via web by fred lopez No access
ELE12-03091 Final1/22/20131/23/20131/23/2013 10:16:32 AMAPART
Dave ###-#### >> Inspection requested via web by Patrick D Gill partial final for west half only
ELE13-00108 Rough-In Permanent Service1/22/20131/23/20131/23/2013 9:33:02 AMAPASS
Call ahead for access Phone #: ###-#### >> Inspection requested via web by Cevyn Recla rough-in p/s u/g n ok
ELE11-01069 Final1/22/20131/23/20131/23/2013 9:01:41 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott final ok
ELE12-02234 Final1/22/20131/23/20131/23/2013 8:43:25 AMAPASS
Electrician on-site, Jerry ###-####
Thank you! Phone #: ###-#### >> Inspection requested via web by Tracy Robertson final ok
ELE13-00135 Permanent Service1/22/20131/23/20131/22/2013 1:37:25 PMAPASS
Phone #: ###-#### >> Inspection requested via web by mike brown p/s u/g rec ok