MEC19-00053
| Rough-in | 1/23/2019 | 1/23/2019 | 1/23/2019 4:00:05 PM | P | PART |
|
|
Inspection requested via web by Konrad Swartz - Man J needs to be stamped by the city and onsite - range hood vent needs to be smooth walled pipe - dryer vent needs to be installed for common laundry room and needs a backdraft damper
|
MEC19-00050
| Rough-in | 1/23/2019 | 1/23/2019 | 1/23/2019 3:48:36 PM | P | PART |
|
|
Inspection requested via web by Konrad Swartz - Man J needs to be stamped by the city and onsite - range hood vent needs to be smooth walled pipe - one dryer vent needs new back draft damper installed - one unit has line set insulation that needs fixed
|
MEC18-06138
| Pressure Test | 1/17/2019 | 1/23/2019 | 1/23/2019 2:59:41 PM | P | PASS |
|
|
Please call our technician when on way so he can meet you onsite for the flue pressure test: Eric ###-####. Also please call the customer when on way so he can meet you onsite: Chad ###-####. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 5lb flue test ok co ok final ok
|
MEC18-04840
| Final | 1/23/2019 | 1/23/2019 | 1/23/2019 2:25:25 PM | P | FAIL |
|
|
Call 2089064067 when you arrive so we can tell you how to find the key to access the house. Home is vacant. Phone #: ###-#### Inspection requested via web by Les Gargan - gas line at furnace needs a sediment trap after shut off valve -secondary drain needs a wet switch installed. it cant be ran into the pump for the primary drain - A/C needs 20 amp fuses installed at service disconnect - I also noticed a new gas fireplace was installed and vented most likely by another contractor which wasnt permited. fireplace installers need to pull a permit before this mech permit can be finaled
|
MEC19-00213
| Rough-in | 1/22/2019 | 1/23/2019 | 1/23/2019 1:56:23 PM | P | PASS |
|
|
Call jason wtih any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek - R/I ok - 2x 5lb flue test ok -20lb gas pressure test ok
|
MEC18-05047
| Final | 1/23/2019 | 1/23/2019 | 1/23/2019 1:30:05 PM | P | PART |
|
|
Please call Russ, Thank YOU! Phone #: ###-#### Inspection requested via web by Rhonda Marcum - need to see guardrails installed at roof access
|
MEC19-00304
| Final | 1/22/2019 | 1/23/2019 | 1/23/2019 1:11:34 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC19-00287
| Final | 1/21/2019 | 1/23/2019 | 1/23/2019 12:52:14 PM | P | PASS |
|
|
My apologies on this one! Requests inspection only from 12 -1 and a call about 15 minutes prior to inspection. Bhumika Chhabra. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - A/C final co ok
|
MEC18-06065
| Final | 1/18/2019 | 1/23/2019 | 1/23/2019 11:46:25 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 11:30 . Contact for Right Now is Mary ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - this install didnt need a 5lb flue pressure test witness performed 1- 90% furnace was in the garage and 1- 80% furnace inside the house - 2 furnaces ac coil co ok
|
MEC18-05263
| Final | 1/22/2019 | 1/23/2019 | 1/23/2019 10:15:37 AM | A | PASS |
|
|
Please call when you are on your way so we can notify the customer. Thank you. Phone #: ###-#### Inspection requested via web by Dan McFate - furnace only co ok
|
MEC19-00149
| Final | 1/23/2019 | 1/23/2019 | 1/23/2019 9:39:14 AM | A | PASS |
|
|
5lb flue test ok - final ok
|
MEC18-05105
| Final | 1/23/2019 | 1/23/2019 | 1/23/2019 9:17:32 AM | A | PASS |
|
|
andy is contact Phone #: ###-#### Inspection requested via web by Aaron Alandt - final ok
|
MEC17-04523
| Final | 1/22/2019 | 1/23/2019 | 1/23/2019 9:17:08 AM | A | PASS |
|
|
Daniel Sprague Phone #: ###-#### Inspection requested via web by Sheldon Lebow - fireplace final ok
|
MEC18-06136
| Pressure Test | 1/22/2019 | 1/23/2019 | 1/23/2019 8:43:35 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 5lb flue pressure test fail guage was under 5lb Inspection cancelled from web by: Gary Reeves
|
MEC18-06136
| Rough-in | 1/22/2019 | 1/23/2019 | 1/23/2019 8:38:01 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - R/I ok but 5lb flue pressure test fail gauge was under 5lb
|
MEC17-04823
| Mec-Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 8:07:52 AM | | FAIL |
|
|
scheduled inspection with homeowner
|
MEC17-05204
| Mec-Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 8:07:30 AM | | FAIL |
|
|
|
MEC16-05348
| Mec-Request for Extension | 1/22/2019 | 1/23/2019 | 1/23/2019 12:00:00 AM | A | CANC |
|
|
Joshua Phone #: ###-####
|