Inspections for the day of: Monday, January 24, 2011.
Number of inspections: 15
Percentage of inspections complete: 93 %
Percentage of inspections not complete: 7 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS10-00337 BLD-Conference12/21/20101/17/2011 A 
BLD10-01663 BLD-Aging Inspection1/24/20111/24/20111/31/2011 11:29:28 AM PASS
Work is still in progress.
BLD10-00201 BLD-Aging Inspection1/24/20111/24/20111/28/2011 4:58:49 PM PASS
Work is in progress.
BLD06-00945 BLD-Aging Inspection1/24/20111/24/20111/28/2011 4:58:01 PM PEND
BLD06-00940 BLD-Aging Inspection1/24/20111/24/20111/28/2011 3:27:08 PM PEND
BLD10-01989 BLD-Framing/Rough-in1/24/20111/24/20111/24/2011 4:45:49 PMPPASS
greg - above ceiling grid Phone #: ###-####
BLD06-00942 BLD-Aging Inspection1/24/20111/24/20111/24/2011 3:27:09 PM PEND
BLD06-00948 BLD-Aging Inspection1/24/20111/24/20111/24/2011 3:23:19 PM PEND
BLD10-01725 BLD-Aging Inspection10/28/20101/24/20111/24/2011 3:21:07 PMACANC
BLD10-01725 DOC - Permit Expired1/24/20111/24/20111/24/2011 3:20:53 PMPPASS
BLD10-02817 BLD-Framing/Rough-in1/24/20111/24/20111/24/2011 2:44:07 PMPFAIL
Rustin Phone #: ###-####. Ok to insulate. Needs to modify scope of work to reflect the bathroom upstairs as being finished and not storage as noted on approv ed plans. Also noted excessive notching and bored holes in 2x10 floor joist were holes and notches are not allowed per IRC. Noted to contractor that they would need to justify in place work with engineering or use the enginnered floor joist shown on approved plans.
GCB10-00056 GCB-Framing1/21/20111/24/20111/24/2011 10:38:35 AMAPART
Scope: Framingcontact: John @ ###-####. More of a building conferance. Needs to get electrical work installed and inspected, complete airseal package. Also neted windows installed are used, must meet .35 max u-factor per nfcr and must be tempered if in hazordous location. Will call back for formal framing inspection once other noted items are completed.
BLD04-00469 BLD-Final1/21/20111/24/20111/24/2011 9:26:38 AMAPASS
holly Phone #: ###-####. All issues resolved. Ok for perm occ.
BLD10-00941 DOC-Permit Expired1/24/20111/24/20111/24/2011 12:00:00 AM DONE
Permit expired by limitations.
BLD10-01072 DOC-Permit Expired1/24/20111/24/20111/24/2011 12:00:00 AM DONE
Permit expired by limitations.