Inspections for the day of: Friday, January 24, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04867 Final1/24/20201/24/20201/24/2020 2:04:25 PMPNH
danny Phone #: ###-####
No answer at door, left card. Recall when accessible.
ELE19-04265 Electrical Rough-In1/24/20201/24/20201/24/2020 1:42:48 PMPCANC
Shane Phone #: ###-####
Needed a conference.
ELE19-04265 Conference1/24/20201/24/20201/24/2020 1:42:48 PMPDONE
Shane Phone #: ###-####
Wiring not installed yet.
Discussed required paddle fan rated boxes needed for paddle fans in bedrooms. Owner wants to loop wiring in ceiling and walls for bathroom lights and cut in when design is finalized. Wanted to put sub-panel in laundry or closet, discussed minimum work space must be present and panel boards are not allowed in closets or bathrooms. Pamphlet given, also discussed options for new service/ panel combos to get rid of additional sub-panel.
ELE19-04265 Conference1/24/20201/24/20201/24/2020 1:42:06 PMPDONE
Shane Phone #: ###-####
Wiring not installed at time of inspection. Discussed paddle fan rated boxes required for paddle fans for bedrooms. Panel location not permitted in closets or bathrooms. Minimum work space shall be provided for panel, laundry area very tight for panel. Discussed service/ panel combos available for get rid of interior panel. Another pamphlet given.
ELE20-00272 Temporary Service1/23/20201/24/20201/24/2020 11:22:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
ELE20-00216 Rough-In Permanent Service1/23/20201/24/20201/24/2020 11:21:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
Rough in ok cover p/s u/g n ok
ELE19-04051 Final1/23/20201/24/20201/24/2020 9:55:42 AMAPASS
Back door will be un locked Phone #: ###-#### Inspection requested via web by kendall bender Final ok
ELE19-00664 Final1/22/20201/24/20201/24/2020 9:13:38 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jim Williams
All electrical shall be completed. Post lights, gate landscape,
406.12- All receptacle outlets shall be tamper resistant type. CAR-15-WH when searched on line should have a TR in the desription.
All was functional just wrong type of receptacles in show areas of house.