ELE19-04867
| Final | 1/24/2020 | 1/24/2020 | 1/24/2020 2:04:25 PM | P | NH |
|
|
danny Phone #: ###-#### No answer at door, left card. Recall when accessible.
|
ELE19-04265
| Electrical Rough-In | 1/24/2020 | 1/24/2020 | 1/24/2020 1:42:48 PM | P | CANC |
|
|
Shane Phone #: ###-#### Needed a conference.
|
ELE19-04265
| Conference | 1/24/2020 | 1/24/2020 | 1/24/2020 1:42:48 PM | P | DONE |
|
|
Shane Phone #: ###-#### Wiring not installed yet. Discussed required paddle fan rated boxes needed for paddle fans in bedrooms. Owner wants to loop wiring in ceiling and walls for bathroom lights and cut in when design is finalized. Wanted to put sub-panel in laundry or closet, discussed minimum work space must be present and panel boards are not allowed in closets or bathrooms. Pamphlet given, also discussed options for new service/ panel combos to get rid of additional sub-panel.
|
ELE19-04265
| Conference | 1/24/2020 | 1/24/2020 | 1/24/2020 1:42:06 PM | P | DONE |
|
|
Shane Phone #: ###-#### Wiring not installed at time of inspection. Discussed paddle fan rated boxes required for paddle fans for bedrooms. Panel location not permitted in closets or bathrooms. Minimum work space shall be provided for panel, laundry area very tight for panel. Discussed service/ panel combos available for get rid of interior panel. Another pamphlet given.
|
ELE20-00272
| Temporary Service | 1/23/2020 | 1/24/2020 | 1/24/2020 11:22:31 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
|
ELE20-00216
| Rough-In Permanent Service | 1/23/2020 | 1/24/2020 | 1/24/2020 11:21:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE19-04051
| Final | 1/23/2020 | 1/24/2020 | 1/24/2020 9:55:42 AM | A | PASS |
|
|
Back door will be un locked Phone #: ###-#### Inspection requested via web by kendall bender Final ok
|
ELE19-00664
| Final | 1/22/2020 | 1/24/2020 | 1/24/2020 9:13:38 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams All electrical shall be completed. Post lights, gate landscape, 406.12- All receptacle outlets shall be tamper resistant type. CAR-15-WH when searched on line should have a TR in the desription. All was functional just wrong type of receptacles in show areas of house.
|