Inspections for the day of: Friday, January 24, 2020.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00220 Final1/24/20201/24/20201/24/2020 3:18:54 PMPFAIL
Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- wet switch ok
- condensate pump needs safety shut down wired and pump is not plugged into a power source
MEC20-00342 Pressure Test1/23/20201/24/20201/24/2020 3:04:35 PMPCANC
Please call Mato''s prior to arrival to ensure on pressure. Phone #: ###-#### >> Inspection requested via web by Andrea Grigsby Inspection cancelled from web by: Andrea Grigsby
MEC20-00313 Final1/23/20201/24/20201/24/2020 3:04:11 PMPNH
Inspection requested via web by Margie Rowe
- no access to home left notice on front door
MEC19-04564 Final1/17/20201/24/20201/24/2020 2:53:41 PMPFAIL
Cust Angie Wallace. Thank you! Phone #: ###-#### Inspection requested via web by Denise Colin
- need to use approved b vent reducer at connection to existing flue
MEC19-05619 Rough-in1/24/20201/24/20201/24/2020 2:39:35 PMPPASS
R/I ok
MEC19-05619 Rough-in1/24/20201/24/20201/24/2020 12:17:54 PMPFAIL
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- approved man j onsite
- line set needs nail plate on 2nd floor
MEC19-05619 Pressure Test1/24/20201/24/20201/24/2020 12:16:39 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 5lb flue pressure test ok
- 20lb gas pressure test ok
- 60lb gas pressure test ok
- tagged meter location
MEC20-00323 Final1/24/20201/24/20201/24/2020 12:15:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Ashley Van Cleave
- 5lb flue pressure test ok
- furnace only co ok
MEC19-04501 Final1/20/20201/24/20201/24/2020 11:58:36 AMAFAIL
Phone #: ###-#### Inspection requested via web by David Youngberg
- line set needs UV protection
- condensate drain needs ran down to ground
- line set penetration at cover needs sealed
MEC19-02764 Final1/21/20201/24/20201/24/2020 11:03:24 AMAFAIL
Please call Vera prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- install co sensors near all bedrooms
- line set arma flex in attic needs replaced and repaired
- A/C needs locking caps
MEC20-00348 Rough-in1/24/20201/24/20201/24/2020 10:27:09 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- R/I ok
MEC20-00348 Pressure Test1/24/20201/24/20201/24/2020 10:26:57 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- 5lb flue pressure test ok
- 20lb gas pressure test ok
- tagged meter location
MEC20-00218 Rough-in1/24/20201/24/20201/24/2020 10:26:29 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- R/I ok
MEC19-04645 Final1/23/20201/24/20201/24/2020 9:39:06 AMAPASS
Please final hvac addition, homeowner will be home to gain access. Please call with any questions. Thank you!! Phone #: ###-#### Inspection requested via web by Gary Duncan
- final ok
MEC20-00345 Rough-in1/23/20201/24/20201/24/2020 9:25:25 AMAPASS
Kevin Phone #: ###-####
- R/I ok
MEC19-04037 Final1/23/20201/24/20201/24/2020 9:06:09 AMAFAIL
ac 4343 Phone #: ###-#### Inspection requested via web by Gary Reeves
- A/C needs locking caps installed on service ports
- A/C needs leveled. Landscaping and site work on side of house is not complete
MEC20-00341 Rough-in1/23/20201/24/20201/24/2020 8:41:35 AMAFAIL
lockbox code is 7777. bj ###-#### Inspection requested via web by william kerwin
- 2nd floor bathroom exhaust needs uncovered and terminated outside in approved manner
- toe kick in kitchen needs ducted out
- fireplace installation instructions
-CSST needs full striker plates where within 2' of stud edge and half striker plates everywhere else
- secondary drain on coil needs wetswitch installed by final and pump safety wired
MEC20-00341 Pressure Test1/23/20201/24/20201/24/2020 8:37:15 AMAPASS
lockbox code is 7777. Inspection requested via web by william kerwin
- 20lb gas pressure test ok
- tagged meter location
MEC19-02892 Mec-Aging Inspection1/24/20201/24/20201/24/2020 8:02:50 AM FAIL
Fail need to schedule re inspection. Permit has not been active since 7-10-19. Permit will expired at next mechanical aging inspection if not active.
MEC19-01306 Mec-Aging Inspection1/24/20201/24/20201/24/2020 8:00:53 AM PASS
Doc Permit Expired ok
MEC19-01306 DOC - Permit Expired1/24/20201/24/20201/24/2020 8:00:28 AMAPASS
Doc Permit Expired ok permit not active
MEC19-01308 Mec-Aging Inspection1/24/20201/24/20201/24/2020 8:00:02 AM PASS
Doc Permit Expired ok
MEC19-01308 DOC - Permit Expired1/24/20201/24/20201/24/2020 7:59:46 AMAPASS
Doc Permit Expired ok permit not active