ELE05-03040
| ELE-Aging Inspection | 1/25/2006 | 1/25/2006 | 1/27/2006 12:25:17 PM | | FAIL |
|
|
nr cor. not made
|
ELE05-03913
| ELE-Aging Inspection | 1/25/2006 | 1/25/2006 | 1/27/2006 8:44:40 AM | | PASS |
|
|
|
ELE06-00183
| Conference | 1/24/2006 | 1/25/2006 | 1/25/2006 4:42:20 PM | A | DONE |
|
|
talked wiyh owner he will have alloway make corrections on p/s done by prior owner on expired permit in 1999
|
ELE05-04023
| Electrical Rough-In | 1/25/2006 | 1/25/2006 | 1/25/2006 4:20:42 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 1/25/2006 at 10:19:37 AM. Contact: ###-####. ceilings ok
|
ELE06-00242
| Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 3:41:31 PM | P | NH |
|
|
Scheduled by a contractor via Hello! on 1/25/2006 at 6:52:33 AM. Contact: ###-####. notice posted called left message
|
ELE06-00291
| Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 2:27:13 PM | P | CANC |
|
|
Chuck ###-####
|
ELE06-00291
| Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 2:26:28 PM | P | PASS |
|
|
chuck ###-#### p/s u/g for meter ok
|
ELE05-04124
| Final | 1/25/2006 | 1/25/2006 | 1/25/2006 1:58:21 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 1/25/2006 at 8:01:22 AM. Contact: ###-####. ok
|
ELE06-00235
| Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 1:36:14 PM | P | FAIL |
|
|
Internet Inspection Request from: Rowdy Monroe r/i & p/s failed cor. posted to both high and low voltage contractors called 250.148 terminate all equip grds together 2 gang box kit.,300.4 nail plates 11/4" for both high and low voltage,220.40 calc and provide p/s of required size for load, low voltage needs conn. for ent at cabinet
|
ELE06-00251
| Rough-In Permanent Service | 1/24/2006 | 1/25/2006 | 1/25/2006 10:19:15 AM | A | PASS |
|
|
charlie; Phone #: ###-#### Internet Inspection Request from: Melyne Davis r/i ok p/s u/g new ok
|
ELE05-04047
| Final | 1/24/2006 | 1/25/2006 | 1/25/2006 9:48:56 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/24/2006 at 1:05:06 PM. Contact: ###-####. fee due and new correction notice posted called left massage violations not corrected new one created 200.6 shall not ID #6 or smaller neutral green identified as white,
|
ELE06-00003
| Final | 1/24/2006 | 1/25/2006 | 1/25/2006 9:10:23 AM | A | PASS |
|
|
added arch fault for bedroom; Phone #: ###-#### Internet Inspection Request from: Dana Moyer
|
ELE06-00026
| Electrical Rough-In | 1/24/2006 | 1/25/2006 | 1/25/2006 8:23:57 AM | A | PART |
|
|
ANY QUESTIONS PLEASE GIVE STEVE NUXOLL A CALL.; Phone #: ###-#### r/i all areas except grid ceiling
|
ELE05-04666
| Conference | 1/24/2006 | 1/25/2006 | 1/24/2006 3:58:09 PM | A | CANC |
|
|
the address 7301 W Emerald Dr. Harmond office\\call ###-#### H P ///cancelled per H.P. 1/24/06 LEG Inspection cancelled from web by: Letitia Mesa
|