ELE05-03294
| ELE-Aging Inspection | 1/25/2006 | 1/25/2006 | 1/26/2006 10:27:11 AM | | DONE |
|
|
called contr to schedule inspection
|
ELE05-03231
| ELE-Aging Inspection | 1/25/2006 | 1/25/2006 | 1/26/2006 9:34:16 AM | | DONE |
|
|
see final
|
ELE06-00150
| Electrical Rough-In | 1/25/2006 | 1/25/2006 | 1/25/2006 4:23:04 PM | P | PART |
|
|
Jeremiah -- spoke with inspector for PM insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong perimeter walls, high wall and baths anop ok to cover
|
ELE05-03924
| Final | 1/25/2006 | 1/25/2006 | 1/25/2006 4:21:45 PM | P | PASS |
|
|
SWIMMING POOL FINAL PLEASE.; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ok to final
|
ELE06-00289
| Rough-In Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 2:35:44 PM | P | FAIL |
|
|
###-#### Nicole or call 8503670 Cody; Phone #: ###-#### Internet Inspection Request from: Nicole Richardson called contr, left corr notice, 314.16 boxes shall be of sufficient size to provide free space for conductors, 300.4(A) & (D) nm cable and edge of holes shall be 1 1/4" from edge of framing member, 725.55 class 2&3 cable shall be separated from power or class 1 circuits, BCC all make-up shall be done, NOTE: 210.52, floor boxes not set, shall maintain spacing at final
|
ELE06-00287
| Rough-In Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 1:35:28 PM | P | PASS |
|
|
Gene ###-#### called contr about front light, ric ok, p/s u/g n ok
|
ELE05-04514
| Electrical Rough-In | 1/24/2006 | 1/25/2006 | 1/25/2006 10:01:31 AM | A | PASS |
|
|
jim bebe; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa walls only east side ok to cover, met elect about 1 1/4" on some mc cable
|
ELE05-03190
| Final | 1/24/2006 | 1/25/2006 | 1/25/2006 10:00:04 AM | A | PASS |
|
|
Bill -- (office ###-####) -- call 1st before insp for access; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok to final
|
ELE05-04323
| Final | 1/24/2006 | 1/25/2006 | 1/25/2006 9:08:03 AM | A | CANC |
|
|
Jeremy -- call 1st before insp for ceiling grid; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong see ri
|
ELE05-04403
| Permanent Service | 1/24/2006 | 1/25/2006 | 1/25/2006 8:50:19 AM | A | PASS |
|
|
CONTACT: LYLE DEAN; Phone #: ###-#### Internet Inspection Request from: Deb McCoy p/s, exst gear, n, ok
|
ELE05-04404
| Permanent Service | 1/24/2006 | 1/25/2006 | 1/25/2006 8:49:27 AM | A | PASS |
|
|
CONTACT: LYLE DEAN; Phone #: ###-#### Internet Inspection Request from: Deb McCoy p/s, exst gear, n, ok
|
ELE05-04323
| Electrical Rough-In | 1/25/2006 | 1/25/2006 | 1/25/2006 12:00:00 AM | A | PASS |
|
|
Jeremy -- call 1st before insp for ceiling grid; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok to cover ceiling
|
ELE05-03131
| Final | 1/25/2006 | 1/25/2006 | 1/25/2006 12:00:00 AM | A | PASS |
|
|
looked at sign
|