PLM06-04121
| Plumbing Rough-in | 1/24/2007 | 1/25/2007 | 1/26/2007 9:47:55 AM | P | PART |
|
|
Andrew Norton is the field contact and he is needing a DWV & Water Plumbing rough-in inspection. Phone #: ###-####-need to fix backgrade on drinking fountain drain, 2" vent in bathroom common wall, show sizing for shock absorbers on bathroom group. ok to insulate water piping.
|
PLM07-00046
| Final | 1/25/2007 | 1/25/2007 | 1/25/2007 4:39:43 PM | P | PASS |
|
|
JOB COTACT: DALE BICKFORD PHONE # ###-#### Phone #: ###-####
|
PLM07-00171
| Groundwork | 1/25/2007 | 1/25/2007 | 1/25/2007 4:25:25 PM | P | PASS |
|
|
Phone #: ###-####-g/w and water service into building pass.
|
PLM06-03355
| Plumbing Rough-in | 1/25/2007 | 1/25/2007 | 1/25/2007 4:17:16 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 1/25/2007 at 7:55:06 AM. Contact: ###-####.
|
PLM07-00175
| Plumbing Rough-in | 1/24/2007 | 1/25/2007 | 1/25/2007 3:40:17 PM | P | PASS |
|
|
Phone #: ###-####
|
PLM05-04309
| Plumbing Rough-in | 1/25/2007 | 1/25/2007 | 1/25/2007 3:22:07 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 1/25/2007 at 11:00:03 AM. Contact: ###-####.-wall rough-in for water on 5th flr in rooms 57601, 57602, 57603, 57604, 57605 pass.
|
PLM06-02785
| Plumbing Rough-in | 1/25/2007 | 1/25/2007 | 1/25/2007 2:44:29 PM | P | PART |
|
|
JOB CONTACT: RYAN MITCHELL PHONE ####-#### Phone #: ###-####-ok to cover bathroom & mop sink walls, except shower area.r/i off this section pass.
|
PLM06-03013
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 1:45:35 PM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 1/24/2007 at 3:28:42 PM. Contact: ###-####. -rpbp needs tested & certified, drain for rpbp needs to handle 35 gpm.
|
PLM07-00088
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 12:25:32 PM | A | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM07-00088
| DOC - Permit Finaled | 1/25/2007 | 1/25/2007 | 1/25/2007 12:25:23 PM | P | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM07-00087
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 12:24:58 PM | A | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM07-00087
| DOC - Permit Finaled | 1/25/2007 | 1/25/2007 | 1/25/2007 12:24:49 PM | P | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM07-00086
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 12:24:28 PM | A | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM07-00086
| DOC - Permit Finaled | 1/25/2007 | 1/25/2007 | 1/25/2007 12:24:18 PM | P | PASS |
|
|
holly; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM05-02183
| Plumbing Rough-in | 1/25/2007 | 1/25/2007 | 1/25/2007 10:58:48 AM | A | FAIL |
|
|
need to support dwv every 4', need to test dwv & water piping, need to add c/o on bar sink as per conversation with home owner.
|
PLM05-02183
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 10:56:09 AM | A | CANC |
|
|
larry; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
PLM06-03464
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 10:30:40 AM | A | FAIL |
|
|
Phone #: ###-####-need to install w/h with approved fittings, need to run t&p, need exspantion tank, need to label non potible water, neeb hbvb on hose adaptor on pressure washer tank.
|
PLM07-00004
| Sprinkler (Final) | 1/25/2007 | 1/25/2007 | 1/25/2007 10:25:42 AM | A | PASS |
|
|
|
PLM06-04136
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 9:42:25 AM | A | PART |
|
|
If questions call Gary @ ###-####. Phone #: ###-#### x0000-need tempered water lo public lavs, need water to drinking fountain.
|
PLM06-03751
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 9:41:06 AM | A | PASS |
|
|
If questions call Gary @ ###-#### Phone #: ###-#### x0000
|
PLM07-00188
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 9:07:57 AM | A | PART |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Victoria Beall-water line pass.
|
PLM07-00189
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/25/2007 9:07:29 AM | A | PART |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Victoria Beall-water line pass.
|
PLM06-03401
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 8:51:36 AM | A | PASS |
|
|
Job #2622 Phone #: ###-####
|
PLM06-03923
| Water and/or Sewer | 1/25/2007 | 1/25/2007 | 1/25/2007 8:51:19 AM | A | PASS |
|
|
|
PLM06-03923
| DOC - Permit Finaled | 1/25/2007 | 1/25/2007 | 1/25/2007 8:51:09 AM | P | PASS |
|
|
|
PLM06-01738
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 8:28:58 AM | A | PASS |
|
|
Phone #: ###-####
|
PLM06-01743
| Final | 1/24/2007 | 1/25/2007 | 1/25/2007 8:28:43 AM | A | PASS |
|
|
Phone #: ###-####
|
PLM07-00186
| Water and/or Sewer | 1/24/2007 | 1/25/2007 | 1/24/2007 8:33:25 AM | P | CANC |
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Victoria Beall Inspection cancelled from web by: Victoria Beall
|