FIR06-00399
| FIR-Aging Inspection | 1/25/2007 | 1/25/2007 | 1/30/2007 9:29:45 AM | | DEFR |
|
|
|
MIS06-00033
| MIS-Aging Inspection | 1/25/2007 | 1/25/2007 | 1/30/2007 9:29:35 AM | | DEFR |
|
|
|
MIS05-00071
| MIS-Aging Inspection | 1/25/2007 | 1/25/2007 | 1/30/2007 9:29:23 AM | | DEFR |
|
|
|
BLD05-02051
| FIRE-Final Inspection | 1/25/2007 | 1/25/2007 | 1/26/2007 4:16:34 PM | P | PASS |
|
|
Fire life safety inspection passed, correction notice issues are complete.
|
BLD05-02962
| FIRE-Final Inspection | 1/25/2007 | 1/25/2007 | 1/26/2007 4:15:50 PM | P | PASS |
|
|
Items on previous c/n are finished, fire life safety passed.
|
BLD05-02052
| FIRE-Final Inspection | 1/25/2007 | 1/25/2007 | 1/26/2007 4:15:16 PM | P | PASS |
|
|
C/N items verified for completion, fire life safety passed.
|
FIR07-00042
| INSP-Final Inspection | 1/25/2007 | 1/25/2007 | 1/26/2007 10:08:10 AM | P | PASS |
|
|
1st floor tenant fire alarm permit work passed inspection.
|
FIR06-00715
| INSP-Alarm Testing | 1/25/2007 | 1/25/2007 | 1/26/2007 9:50:15 AM | P | DEFR |
|
|
Inspection scheduled for 1/26 as agreed.
|
BLD06-01896
| FIRE-Final Inspection | 1/24/2007 | 1/25/2007 | 1/26/2007 8:25:35 AM | P | PASS |
|
|
Fire life safety inspection passed.
|
FIR06-00651
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/26/2007 8:17:39 AM | P | FAIL |
|
|
Per field inspection completed by M. Timmerman defficiencies noted and some revisions will be required.
|
FIR06-00699
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/26/2007 8:14:25 AM | A | PASS |
|
|
Per field inspection completed by M. Timmerman, the hood suppression system operated correctly under test conditions, inspection passed, permit finaled.
|
FIR05-00425
| INSP-Sprinkler Rough-in/Hydro | 1/23/2007 | 1/25/2007 | 1/26/2007 8:11:48 AM | A | PART |
|
|
Completed fire pump field acceptance test including pump curve, flow testing, controller operation, engine drive, and jockey pump. Noted some items in need of revision including removal of the ball valves in the pressure sensing lines (NFPA 20 12.5.2.1.6 B3), the exhaust pipe shall be covered or insulated per 11.5.3.3, repair the leak in the 1/2" cooling line at the engine, provide missing stop button at the controller. Also completed acceptable standpipe flow testing via fire pump and FD pumper vehicle.
|
BLD06-03222
| FIRE-Final Inspection | 1/25/2007 | 1/25/2007 | 1/25/2007 5:43:36 PM | A | PASS |
|
|
Fire life safety passed final inspection.
|
FIR06-00999
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 1:14:01 PM | P | CANC |
|
|
Inspection canceled per phone call from the contractor.
|
FIR06-00946
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 1:13:12 PM | P | CANC |
|
|
Cancel inspection per phone call from contractor.
|
FIR06-00816
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 1:12:19 PM | A | PASS |
|
|
Fire alarm work is satisfactory, permit finaled.
|
BLD06-02877
| FIRE-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 11:51:50 AM | A | PASS |
|
|
Life safety inspection passed.
|
BLD06-01413
| FIRE-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 11:38:04 AM | A | FAIL |
|
|
Final pending the project related fire alarm permit work.
|
FIR06-00985
| INSP-Sprinkler Rough-in/Hydro | 1/24/2007 | 1/25/2007 | 1/25/2007 10:55:04 AM | A | PART |
|
|
UG fire supply line is approved for bury.
|
FIR06-00986
| INSP-Sprinkler Rough-in/Hydro | 1/24/2007 | 1/25/2007 | 1/25/2007 10:54:20 AM | A | PART |
|
|
UG supply line is approved for cover.
|
FIR06-00706
| INSP-Final Inspection | 1/24/2007 | 1/25/2007 | 1/25/2007 10:53:41 AM | A | PASS |
|
|
Fire sprinkler permit passed final inspection.
|