Inspections for the day of: Thursday, January 25, 2018.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03310 ELE-Aging Inspection1/25/20181/25/20181/25/2018 3:40:34 PM FAIL
waiting on contractor
ELE17-01458 Permanent Service1/25/20181/25/20181/25/2018 3:28:36 PMPPASS
Inspect burn tower service to energize Phone #: ###-#### Inspection requested via web by Jeremy Cloud...p/s u/g new ok
ELE17-01458 Electrical Rough-In1/25/20181/25/20181/25/2018 3:28:14 PMPPASS
Inspect burn tower service to energize Phone #: ###-#### Inspection requested via web by Jeremy Cloud....floor 3, floor 5, and roof top slab for concrete pours verified ok...extensions from each floor
ELE17-02340 Final1/25/20181/25/20181/25/2018 2:35:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by John VanZandt...all outlets in garages shall have GFI protection
ELE17-03299 Final1/25/20181/25/20181/25/2018 2:34:20 PMPPASS
Phone #: ###-#### Inspection requested via web by John VanZandt...ok to final
ELE17-04057 Final1/24/20181/25/20181/25/2018 1:37:07 PMPFAIL
Phone #: ###-#### Inspection requested via web by Steve Craig....1)
all outlets need completed with power-outlets below counter have no power, unable to verify GFI protection
2) OCPD on hot wells are too large-15A max on nameplate
3) roof top units need labelled
4) cooler cases need finished, outlets need mounted to proper cover plates-2 of them
ELE18-00229 Final1/25/20181/25/20181/25/2018 12:44:41 PMPNH
Contact is Todd Sellman if needed. Phone #: ###-#### Inspection requested via web by Todd Sellman...unable to get access to where work was done...contractor needs to schedule time to meet to get access
ELE18-00148 Final1/25/20181/25/20181/25/2018 12:18:36 PMPNR
Door code is 1420 Phone #: ###-#### Inspection requested via web by MIKE HAGERTY..
not ready...waiting on occupency sensors
ELE17-04354 Final1/25/20181/25/20181/25/2018 12:14:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Barbara Szurgot...ok to final
ELE17-03384 Electrical Rough-In1/25/20181/25/20181/25/2018 11:49:45 AMPCANC
Please add final inspection for Friday if possible.

Thanks Phone #: ###-#### Inspection requested via web by CHRIS CARMINE...needed final, rescheduled for friday 1/26
ELE17-02858 Final1/24/20181/25/20181/25/2018 11:02:29 AMAPASS
Final Electrical Inspection Phone #: ###-#### Inspection requested via web by Bryan Atkins...ok to final
ELE17-03605 Final1/24/20181/25/20181/25/2018 10:16:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
ELE17-03433 Final1/24/20181/25/20181/25/2018 10:12:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Tyler Ridley...

1) breaker lock oput needs installed on OCPD of dishwasher circuit
2) romex shall be completely protected from physical damage-kit island flex too short
3) where metal flex is used it shall terminate in a box with means of attachment-metal box for island outlet
4) the panel shall be labelled completely and legibily-breakers mark spares are powering circuits
5) down stairs bed nedds outlet installed on 30" wall space-was not completed as per rough in inspection
ELE18-00323 Electrical Rough-In1/24/20181/25/20181/25/2018 9:14:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Jesse Fuentes...ok to cover
ELE17-04335 Final1/24/20181/25/20181/25/2018 8:33:53 AMAPASS
if you have trouble getting in, please call Chase at ###-####
thank you. Phone #: ###-#### Inspection requested via web by Cyndi Dale...ok to final