Inspections for the day of: Thursday, January 25, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-01210 PLM-Aging Inspection1/25/20181/25/20181/30/2018 11:07:48 AM PEND
contractor to schedule
PLM17-03952 Final1/23/20181/25/20181/26/2018 10:46:36 AMPFAIL
Phone #: ###-#### Inspection requested via web by Dennis Seward.
1. Pipe the electric water heater t&p drain to an approved waste location with an air gap.
2. Seperate the carbonator waters from all other lines.
3. Install double check valves at the coffee/tea makers and ice machines.
PLM17-03289 Final1/25/20181/25/20181/25/2018 3:45:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Tom Maxwell.
The water heater drain pan must be metallic and drain to the hub drain or outside.
PLM17-02641 Final1/25/20181/25/20181/25/2018 3:43:47 PMPFAIL
Phone #: ###-#### Inspection requested via web by Tom Maxwell.
The water heater drain pan must be metallic and drain to the hub drain or outside.
PLM18-00346 Groundwork1/25/20181/25/20181/25/2018 3:07:40 PMPPASS
Please accommodate a 4 o''clock inspection. Phone #: ###-#### Inspection requested via web by David Scaggs
PLM18-00321 Final1/24/20181/25/20181/25/2018 2:34:10 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
PLM18-00343 Final1/25/20181/25/20181/25/2018 2:18:21 PMPPASS
Front door code1420 Phone #: ###-#### Inspection requested via web by Robert Madrigal
PLM17-03094 Plumbing Rough-in1/25/20181/25/20181/25/2018 2:08:13 PMPFAIL
Check grade on the overhead and trap arms
PLM17-03093 Plumbing Rough-in1/24/20181/25/20181/25/2018 2:07:26 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM17-03675 Plumbing Rough-in1/24/20181/25/20181/25/2018 1:51:49 PMPCANC
Phone #: ###-#### Inspection requested via web by Brian Johansen. Already inspected
PLM17-04859 Plumbing Rough-in1/24/20181/25/20181/25/2018 1:39:01 PMPPASS
JOB # 51171 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-00298 Plumbing Rough-in1/25/20181/25/20181/25/2018 1:28:55 PMPPASS
Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
PLM18-00325 Groundwork1/24/20181/25/20181/25/2018 1:03:58 PMANR
JOB CONTACT - MEL ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
The groundwork isn't complete. The back to back wc's must enter through a fixture fitting.
An approved set of plans must be provided for inspection
PLM18-00328 Water Heater Final1/24/20181/25/20181/25/2018 10:06:33 AMANH
Jeffrey ###-#### Phone #: ###-#### Inspection requested via web by curtis rowe
PLM18-00323 Water Heater Final1/24/20181/25/20181/25/2018 9:39:57 AMAFAIL
homeowner to be present for inspection, George T. Phone #: ###-#### Inspection requested via web by Mike Dunson.
Provide co detectors within 20 feet of all bedrooms.
PLM17-04921 Final1/24/20181/25/20181/25/2018 9:02:15 AMAFAIL
Phone #: ###-#### Inspection requested via web by Branden Steers.
Pipe the t&p to the garage floor then reschedule
PLM18-00177 Groundwork1/25/20181/25/20181/25/2018 8:37:23 AMAPASS
Hi Dan, Groundwork for new drinking fountain by NW front entrance behind visqueen area. Any questions call Jim Little. Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM17-02069 PLM-Aging Inspection1/25/20181/25/20181/25/2018 8:09:57 AM PASS
PLM17-02069 DOC - Permit Finaled1/25/20181/25/20181/25/2018 8:09:46 AMPPASS